| CS Number | SF Case | Epicor Case | Store | City | State | Serial | Unit Type | Zone | SLA | Dispatch | Appts | TD (Hrs) | Entry Date/Time | Dispatched | First Onsite | Completed | Resolution | Resolution Notes | Reason | Parts |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CSDI0014738 | 00448267 | Starbucks - 7534 | New York | NY | UG-39837 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-14 13:09 | 2026-09-14 13:40 | Duplicate | UG-39837 - 00448268 - 00058162 | Duplicate issue | ||||||
| CSDI0014715 | 00447966 | Starbucks - 8291 | Atlanta | GA | UG-38065 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 21 | 2026-09-13 12:51 | 2026-09-13 19:11 | 2026-09-14 08:16 | 2026-09-14 09:43 | Dispatched |
At arrival right BA is not in service. Inspected and cleaned...
At arrival right BA is not in service. Inspected and cleaned. Nothing unusual found. Reseated BA and came into service. Manager Tamika tested it successfully. Manager also complained about bottom.storage vault not opening. Handle is dragging. This safe has been vandalized in the past. The corner of the door has been hammered and very likely out of shape. You basically have to press the bottom corner of the door with your foot to get handle to slide up and down somewhat free. Inspected one of the bushings and indeed there is a lot of grinding going on. Called Tidel with pictures of the issue to take some type of an action.;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014709 | 00447877 | Starbucks - 8808 | Chicopee | MA | UG-41511 | Smart Safe | ZONE1 | NBD | 0 | 22 | 2026-09-12 20:45 | 2026-09-12 20:45 | 2026-09-13 18:55 | Dispatched |
Per Deposita quote was not approved and was advised to close...
Per Deposita quote was not approved and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014717 | 00447972 | Starbucks - 13210 | Alabaster | AL | UG-38094 | Smart Safe | ZONE1 | NBD | 5 | 2026-09-13 13:20 | 2026-09-13 18:34 | Phone Fix |
Per Deposita quote was not approved and was advised to close...
Per Deposita quote was not approved and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014706 | 00447830 | Starbucks - 11089 | Atwater | CA | UG-43761 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 27 | 2026-09-12 13:25 | 2026-09-12 14:43 | 2026-09-13 16:03 | 2026-09-13 16:48 | Dispatched |
Arrived on site. Spoke to Manger Olivia. Site had replace ac...
Arrived on site. Spoke to Manger Olivia. Site had replace acceptor when part got delivered Saturday. Safe acceptors are working. Old ba was thrown away to the trash by costumer. No tracking or part available to send back to tidel. Called tidel and spoke to Akram. Informed him that costumer had thrown away the old part and Burroughs will not be responsible for part. Got the clear from tidel to close call. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014701 | 00447808 | Starbucks - 2470 | Mt. Prospect | IL | UG-41175 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 24 | 2026-09-12 11:34 | 2026-09-12 13:21 | 2026-09-13 10:55 | 2026-09-13 11:36 | Dispatched |
Arrived. Talked with Sai about issue. Replaced left bv. Test...
Arrived. Talked with Sai about issue. Replaced left bv. Tested. All good. Checked voltage test and ftp test. All passed. Safe is up;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014553 | 00446503 | Starbucks - 9549 | Norco | CA | UG-43605 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 115 | 2026-09-08 16:44 | 2026-09-08 19:55 | 2026-09-09 14:30 | 2026-09-13 11:14 | Dispatched |
Part waiting ;
Part waiting ;
On arrival poc Valerie gave me...
Part waiting ;
Part waiting ;
On arrival poc Valerie gave me access to safe and parts I noticed that the safe stated it was online. I did a successful xml and ftp test then called g4s I spoke with Chris he was able to see the safe and stated that the safe has been online for a couple of days.hr said it was ok and close call and did not need to replace any parts. Unit is up and running upon departure
Modem return tracking 792724961871;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014527 | 00445250 | Starbucks - 11698 | Bastrop | TX | ZA-03150 | Smart Safe | ZONE1 | NBD | CPI | 1 | 227 | 2026-09-03 23:34 | 2026-09-04 10:36 | 2026-09-05 09:00 | 2026-09-13 10:32 | Dispatched |
Joe Robles B21, 9/13/26 10:31
P: original issue was describe...
Joe Robles B21, 9/13/26 10:31
P: original issue was described as, ? bottom handle is broken?
C: on site saw that lower drop volt ball handle was missing/ broken off
R:contacted tidel, spoke with Meme, pacn# 2104595228, opened door, removed door cover and disassembled door slide. Using protective equipment drilled out broken thread from door slide. Rethreaded door slide for new ball handle. Secured ball handle with locktite, had customer test opening door, tested fine. Cleaned safe display and blew out bill acceptor. Advised customer to be cautious of liquid or food damage to the safe. Also informed customer to allow Loctite to harden for a few hours before putting too much pressure on the door handle.
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014708 | 00447869 | Starbucks - 10981 | Toledo | OH | UG-44346 | Smart Safe | ZONE1 | NBD | CPI | 1 | 15 | 2026-09-12 19:48 | 2026-09-13 06:21 | 2026-09-13 10:05 | 2026-09-13 10:34 | Dispatched |
Upon arrival bill acceptor jammed with old soft bills.Custom...
Upon arrival bill acceptor jammed with old soft bills.Customer accessed acceptor and removed jammed bill. Cleaned all rollers and sensors from both acceptors. Tested good by customer
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014698 | 00447762 | Starbucks - 11794 | Lafayette | IN | UG-43859 | Smart Safe | ZONE2 | NBD | Burroughs | 1 | 28 | 2026-09-12 05:35 | 2026-09-12 09:46 | 2026-09-13 09:20 | 2026-09-13 09:57 | Dispatched |
Replaced broken touch screen display. Return tracking 1Z7611...
Replaced broken touch screen display. Return tracking 1Z7611409054525384. ;
|
Resolved - by field engineer with part replaced (in scope) |
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH ...
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB)
|
|
| CSDI0014682 | 00447617 | Starbucks - 17861 | Granite Bay | CA | UG-44334 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 28 | 2026-09-11 14:18 | 2026-09-11 14:46 | 2026-09-12 18:27 | 2026-09-12 18:51 | Dispatched |
Upon arrival met with Manager Brandon, granted access to uni...
Upon arrival met with Manager Brandon, granted access to unit. Inspected printer and found to have failed. Replaced and tested successfully. At this time machine is up and operational.;
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402R (PRINTER KFI) | |
| CSDI0014707 | 00447850 | Starbucks - 19781 | Tulsa | OK | UG-44153 | Smart Safe | ZONE3 | NBD | 2 | 2026-09-12 16:04 | 2026-09-12 18:52 | Phone Fix |
Hello Sesami Team,
Approval for the referenced Work Task wa...
Hello Sesami Team,
Approval for the referenced Work Task was not received within the allotted timeframe. As a result, we are unable to proceed with the service call.
Please close the ticket accordingly.
|
Resolved - by customer | ||||||
| CSDI0014674 | 00447417 | Starbucks - 17936 | Lacey | WA | UG-41181 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 33 | 2026-09-11 08:31 | 2026-09-11 14:09 | 2026-09-12 17:13 | 2026-09-12 17:46 | Dispatched |
Arrived on site. Received access from MOD V. She told me the...
Arrived on site. Received access from MOD V. She told me the right acceptor isn’t working. Found glue stuck in acceptor. Removed glue, and replaced acceptor with part received. Tested new acceptor no issues. Call complete ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014638 | 00446937 | Starbucks - 56067 | Galt | CA | ZA-04627 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 71 | 2026-09-09 18:06 | 2026-09-09 19:49 | 2026-09-12 16:24 | 2026-09-12 17:11 | Dispatched |
Both Bvs Not Functioning
test with MOD
seated cassettes
cas...
Both Bvs Not Functioning
test with MOD
seated cassettes
cassettes not fully sested by courier
Acceptors showing as unavailable on arrival. Removed, cleaned, and reseated both acceptors. Initialization ran on, and indicators flashed yellow. Opened acceptor door, finding cassettes not fully seated. Seated both cassettes. MOD Selena dropped bills on both sides successfully. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014704 | 00447822 | Starbucks 6808 | Houston | TX | ZA-04312 | Smart Safe | ZONE1 | NBD | CPI | 1 | 4 | 2026-09-12 12:29 | 2026-09-12 13:30 | 2026-09-12 15:10 | 2026-09-12 16:22 | Dispatched |
***TECH#196 CATO***
On site 9/12@3:15pm. On arrival BA2 was ...
***TECH#196 CATO***
On site 9/12@3:15pm. On arrival BA2 was showing jammed. There were food particles and syrup in the note feeder. I removed the rollers and cleaned it out best I could but it still would not work, the syrup seeped all up inside and was gumming it up. Replaced note feeder and MOD tested
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014672 | 00447368 | Starbucks - 24476 | Arlington | VA | UG-38299 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 34 | 2026-09-11 06:05 | 2026-09-11 08:31 | 2026-09-12 15:01 | 2026-09-12 16:14 | Dispatched |
Unit was down with both bill validator jam and printer, not ...
Unit was down with both bill validator jam and printer, not printing. I did a diagnostic and found that the bill validators had coffee beans and a pennies in both, I cleared the jam had manager do drop it passed. I fix the printer, it was loaded incorrectly. I had manager do print tests. It passed, I put unit back in service unit is up and open;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014677 | 00447503 | Starbucks - 14684 | Killeen | TX | ZA-04302 | Smart Safe | ZONE1 | NBD | CPI | 1 | 26 | 2026-09-11 10:47 | 2026-09-11 14:47 | 2026-09-12 11:49 | 2026-09-12 12:45 | Dispatched |
On arrival the customer reported BA 1 failure status. I foun...
On arrival the customer reported BA 1 failure status. I found coffee grounds and beans all inside the BNF. I replaced the BA 1 assembly including the BNF and the BA. Still failure. I swapped BA1 and BA2 and the failure issue remains in BA1. I removed the BA assembly and tested voltage on the 7th and 8th pin on the MEI card. I replaced the MEI card. Still failure. I then replaced the entire BA housing assembly and that seemed to do the trick. Unit is dropping as designed with no issues. The cable was reported to be replaced, but its the part that the MEI card plugs into, rather than the cable itself. Call completed.
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014681 | 00447600 | Starbucks - 47413 | Matawan | NJ | UG-39842 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 23 | 2026-09-11 13:48 | 2026-09-11 15:59 | 2026-09-12 11:35 | 2026-09-12 12:29 | Dispatched |
Waited location was busy once seen manager rbv kept cycling....
Waited location was busy once seen manager rbv kept cycling. Replace return 1Z7611409053809436;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014699 | 00447767 | Starbucks - 50611 | New York | NY | UG-38355 | Smart Safe | ZONE1 | NBD | 5 | 2026-09-12 07:06 | 2026-09-12 12:27 | Phone Fix |
Approval for the referenced Work Task was not received withi...
Approval for the referenced Work Task was not received within the allotted timeframe. As a result, we are unable to proceed with the service call.
Please close the ticket accordingly.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014703 | 00447813 | Starbucks - 9575 | Waxahachie | TX | ZA-03285 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-12 11:51 | 2026-09-12 12:13 | Phone Fix | Lindsay with Deposita Called to request to cancel ticket | Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014670 | 00447363 | Starbucks - 14389 | Webster | TX | ZA-04265 | Smart Safe | ZONE1 | NBD | CPI | 1 | 30 | 2026-09-11 04:47 | 2026-09-11 08:50 | 2026-09-12 10:30 | 2026-09-12 10:48 | Dispatched |
***TECH#196 CATO***
On site 9/12@10:30am. On arrival Jolene ...
***TECH#196 CATO***
On site 9/12@10:30am. On arrival Jolene stated they were able to correct the issue, that both doors are opening now. She allowed me to check the safe and confirm both doors are functioning as normal. No parts replaced, see photos attached
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014659 | 00447232 | Starbucks - 65492 | Frisco | TX | UG-44306 | Smart Safe | ZONE1 | NBD | CPI | 1 | 44 | 2026-09-10 14:36 | 2026-09-10 18:32 | 2026-09-12 09:37 | 2026-09-12 10:00 | Dispatched |
Upkn arriival bill acceptor not taking bills. Removed accept...
Upkn arriival bill acceptor not taking bills. Removed acceptor and found 2 coins and coffee beans jammed. Removed coins and coffee beans. Cleaned all rollers. Unit ready to accept bills. Customer stated didn?t have any money to test unit.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014669 | 00447350 | Starbucks - 19258 | Houston | TX | ZA-04377 | Smart Safe | ZONE1 | NBD | CPI | 1 | 34 | 2026-09-10 23:19 | 2026-09-11 08:21 | 2026-09-12 08:31 | 2026-09-12 09:16 | Dispatched |
991 Z@C@Rias
Problem
Both BA
Solved
I came to site were ...
991 Z@C@Rias
Problem
Both BA
Solved
I came to site were the last call C148192 i ordered parts. I got them from the back of the store.i replaced the parts I ordered and tested okay
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014676 | 00447498 | Starbucks - 2863 | Piscataway | NJ | UG-38846 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 22 | 2026-09-11 10:35 | 2026-09-11 15:00 | 2026-09-12 07:56 | 2026-09-12 08:25 | Dispatched |
Problem is door dose open but hitting cabinet. Location may ...
Problem is door dose open but hitting cabinet. Location may need to cut small edge of bottom counter so door can open fully;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014695 | 00447736 | Starbucks - 11521 | Columbia | MO | UG-39716 | Smart Safe | ZONE3 | NBD | 3 | 2026-09-11 20:00 | 2026-09-11 23:22 | Phone Fix | Deposita did not approve | Resolved - by customer | ||||||
| CSDI0014363 | 00442142 | Starbucks - 9590 | Phoenix | AZ | UG-44098 | Smart Safe | ZONE1 | NBD | Burroughs | 5 | 400 | 2026-08-26 06:52 | 2026-08-26 20:16 | 2026-08-28 12:38 | 2026-09-11 22:02 | Dispatched |
Arrived to find printer working fine mgr said she called bac...
Arrived to find printer working fine mgr said she called back to advise but they still sent printer pcb anyway replaced ball handle and had to get drawer unstuck. Then couldn't get drawer to latch close. Tried several different adjustments may just need a hammer which I dont have due to being in a rental truck. Interrupted call for another tech to try. Left parts on site on mgr desk ;
Arrived to find printer working fine mgr said she called back to advise but they still sent printer pcb anyway replaced ball handle and had to get drawer unstuck. Then couldn't get drawer to latch close. Tried several different adjustments may just need a hammer which I dont have due to being in a rental truck. Interrupted call for another tech to try. Left parts on site on mgr desk ;
On site manager infrom tech came and looked at safe. Wont let me work on safe. ;
On site manager infrom tech came and looked at safe. Wont let me work on safe. ;
Inspected drawer and found drawer front locking plate slightly bent and worn bushings. Contacted and sent photos to Sesami for drawer approval. ;
Inspected drawer and found drawer front locking plate slightly bent and worn bushings. Contacted and sent photos to Sesami for drawer approval. ;
Tidel has not sent part yet will arrive Tuesday ;
Tidel has not sent part yet will arrive Tuesday ;
New drawer arrived but while swapping part found new door did not have cutout for wires. Swapped door fronts so wires would reach. Door still rubbing while closing tried both rails. And made many adjustments and got as good as I could, unit up and open.;
|
Resolved - by field engineer with part replaced (in scope) |
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-101S (PC...
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-101S (PCB PRINTER - KFI), 208-4760-102S (STORAGE DRAWER ASSY)
|
|
| CSDI0014692 | 00447717 | Starbucks - 2583 | Poland | OH | UG-39984 | Smart Safe | ZONE1 | NBD | 2 | 2026-09-11 17:44 | 2026-09-11 19:03 | Duplicate |
A technician is already being dispatched to this location un...
A technician is already being dispatched to this location under work order 00447196.
Would the technician be able to investigate and possibly resolve this issue during that visit, rather than the store incurring an additional labor and travel charge? Since no parts are required for this request, I wanted to see if it could be addressed at once
|
Duplicate issue | ||||||
| CSDI0014639 | 00446949 | Starbucks - 9346 | Moreno Valley | CA | UG-43940 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 47 | 2026-09-09 19:16 | 2026-09-09 20:55 | 2026-09-11 17:33 | 2026-09-11 18:39 | Dispatched |
Arrived on site and spoke with MoD Jessica. She was pleased...
Arrived on site and spoke with MoD Jessica. She was pleased I had been dispatched to work on the safe. Immediately noticed a slight indentation on the Display. When i attempted to use it though the calibration was off. I shut off the safe and reseated the connections and booted it back up while tapping on the display to calibrate. This led me to the calibration screen but I needed to apply a lot of pressure to get a resulting touch and even then it was inconsistent. I swapped out the old display for the one Tidel shipped and it immediately worked. Tested it by authorizing the PACN in my notes and opening doors. Allowed Jessica to also log in. Everything works properly;
|
Resolved - by field engineer with part replaced (in scope) |
210-0510-001R (PCB CONTROL PANEL RECONDITIONED (NON CUSTOMER...
210-0510-001R (PCB CONTROL PANEL RECONDITIONED (NON CUSTOMER SPECIFIC) (S-4)), 633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB)
|
|
| CSDI0014523 | 00445223 | Starbucks - 28814 | Watsonville | CA | UG-43942 | Smart Safe | ZONE1 | NBD | Burroughs | 3 | 193 | 2026-09-03 17:38 | 2026-09-04 15:20 | 2026-09-06 12:27 | 2026-09-11 18:13 | Dispatched |
Tool required, will return after lunch, please do not move c...
Tool required, will return after lunch, please do not move call as I left my tool bag there and need to return.
;
Tool required, will return after lunch, please do not move call as I left my tool bag there and need to return.
;
The bottom drawer vault threaded stud with ball handle broke off, leaving the threaded Rod portion stuck inside sliding locking Bolt. Drive to Home Depot to purchase the correct size thread extractor and drilled broken threaded nub and use extractor to remove it from the sliding locking Bolt. Now it is ready to install the new threaded stud with round plastic ball handle and when I open the package, I am served that they sent the wrong part, it was the plastic handle that is used on acceptor vaults and this lower drawer Style has a sliding bolt lock that uses a threaded rod with a round plastic ball on the end to slide horizontally to lock and unlock.;
The bottom drawer vault threaded stud with ball handle broke off, leaving the threaded Rod portion stuck inside sliding locking Bolt. Drive to Home Depot to purchase the correct size thread extractor and drilled broken threaded nub and use extractor to remove it from the sliding locking Bolt. Now it is ready to install the new threaded stud with round plastic ball handle and when I open the package, I am served that they sent the wrong part, it was the plastic handle that is used on acceptor vaults and this lower drawer Style has a sliding bolt lock that uses a threaded rod with a round plastic ball on the end to slide horizontally to lock and unlock.;
The threaded rod with round plastic ball handle had broken off inside of their sliding drawer lower vault door leaving the threaded Rod piece stuck inside the sliding bolt assembly. It was very difficult to extract the broken piece of threaded rod which required disassembly of the sliding Bolt from boat door to drill and extract the broken piece. Reassemble and install the correct part that they sent the second time which is a short threaded rod with a round plastic ball on the end for the sliding bolt lock assembly and tighten it securely. Test open and close the sliding bolt lock assembly with the vault door open, several times to ensure correct and smooth operation. Close and secure the sliding drawer vault door and then observe the manager testing- opening and closing the lower sliding drawer vault door several times to their satisfaction and they were very happy of how smooth and easy it was to operate. The manager Nicole also said that sometimes that bill validators reject notes so I removed and thoroughly cleaned inside them and observed her testing with several bills, successful. Customer safe is now operating properly and back in service.;
|
Resolved - by field engineer with part replaced (in scope) |
205-7842-001S (PLASTIC HANDLE AUTOLOCK SHORT), 502-1363-001S...
205-7842-001S (PLASTIC HANDLE AUTOLOCK SHORT), 502-1363-001S (HANDLE BALL BILL VAL DOOR)
|
|
| CSDI0014678 | 00447514 | Starbucks - 2285 | Troy | MI | UG-41509 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 6 | 2026-09-11 11:03 | 2026-09-11 15:19 | 2026-09-11 16:47 | 2026-09-11 17:04 | Dispatched | Arrived on site, cleared the jamm and tested with Merin; | Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014640 | 00447019 | Starbucks - 55620 | Allen | TX | ZA-03169 | Smart Safe | ZONE1 | NBD | CPI | 1 | 32 | 2026-09-10 08:16 | 2026-09-10 12:52 | 2026-09-11 15:51 | 2026-09-11 16:26 | Dispatched |
On arrival, MOD stated that both bill acceptors were having ...
On arrival, MOD stated that both bill acceptors were having issues. Left side would not feed at all while the right side would intermittently not feed. On inspection, found a dime stuck in the left BA feeder. Removed dime carefully to avoid damage to feeder. Cleaned out all dust and debris from feeder. Cleaned all sensor lenses. Right side BA needed cleaning. Wheels inside feeder had reduced grip due to dirt deposits. Cleaned out all dust and dirt. Cleaned wheels and all sensor lenses. Installed both BAs into safe. Used bill authentication and white 98 paper to test feeding of both acceptors. Both fed correctly multiple times witout issues. MOD then tested by depositing $1 into each acceptor successfully. Safe is back in full operation. Job complete.
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014609 | 00446891 | Starbucks - 11281 | Forest Park | OH | UG-38059 | Smart Safe | ZONE1 | NBD | CPI | 2 | 48 | 2026-09-09 16:00 | 2026-09-09 18:23 | 2026-09-10 10:49 | 2026-09-11 16:03 | Dispatched |
Incomplete Biggerstaff 899 act of God power loss was on site...
Incomplete Biggerstaff 899 act of God power loss was on site for about an hour and 45 minutes. Most of it was on hold with deposit called tier 3 after I lost connection with deposit again and they didn?t call me back worked with Eric. He got me on the phone with a Patrick made sure we had my phone number because he had to go when Eric left we lost connection. I waited about 15 minutes. Patrick never called me back called again. Waited about 11 minutes found out from Angel that I have the wrong production file. I need the Starbucks specific production file called sesame worked with Morgan got that correct production file as soon as I was beginning to start site lost power doors were locked open luckily after trying to manually trigger doors and finding out that the accepter vault is a swing bolt I realize the ups for their pos they had power plugged it into the UPS just to fire up the doors and secure the safe let tier 3 sesami erich know will return with correct production file later
Incomplete Biggerstaff 899 act of God power loss was on site for about an hour and 45 minutes. Most of it was on hold with deposit called tier 3 after I lost connection with deposit again and they didn?t call me back worked with Eric. He got me on the phone with a Patrick made sure we had my phone number because he had to go when Eric left we lost connection. I waited about 15 minutes. Patrick never called me back called again. Waited about 11 minutes found out from Angel that I have the wrong production file. I need the Starbucks specific production file called sesame worked with Morgan got that correct production file as soon as I was beginning to start site lost power doors were locked open luckily after trying to manually trigger doors and finding out that the accepter vault is a swing bolt I realize the ups for their pos they had power plugged it into the UPS just to fire up the doors and secure the safe let tier 3 sesami erich know will return with correct production file later
Arrived on site called G4S was on hold for almost 30 minutes. Got a hold of John. We did the production file things were missing so we rebooted it again. Seems like it finished the production after the second time then we had connectivity issues came down to one incorrect number. Finally got everything communicating manually said that that has a door one in door two added mod in worked with mod Evelyn John let me know to tell him not to use the safe for a couple hours as it should get configured correctly in the background and update. It?s good to go. He told me.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014665 | 00447309 | Starbucks - 58526 | Union | NJ | UG-39766 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 19 | 2026-09-10 18:05 | 2026-09-11 08:35 | 2026-09-11 12:37 | 2026-09-11 13:43 | Dispatched |
Checked machine for any problems. Open maintenance door with...
Checked machine for any problems. Open maintenance door with no problems. Replaced left BV broken test unit ok. Spoke to Dani about the maintenance door maybe they was using the wrong code. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014644 | 00447014 | Starbucks - 10827 | Bloomington | IN | UG-38606 | Smart Safe | ZONE2 | NBD | Burroughs | 1 | 30 | 2026-09-10 07:53 | 2026-09-10 08:45 | 2026-09-11 11:30 | 2026-09-11 13:19 | Dispatched |
Both BAs are working. I had to wait for the manager and then...
Both BAs are working. I had to wait for the manager and then take out and put back in the acceptors and they both accepted notes. Safe is in service.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014652 | 00447177 | Starbucks - 8114 | Susanville | CA | UG-43751 | Smart Safe | ZONE4 | NBD | Burroughs | 1 | 24 | 2026-09-10 12:52 | 2026-09-10 14:33 | 2026-09-11 11:29 | 2026-09-11 12:32 | Dispatched |
Right BV failure on arrival, removed and cleaned but problem...
Right BV failure on arrival, removed and cleaned but problem remained. Replaced right BV and tested. No return label on package, waiting for label to be emailed from Tidel and will update ticket ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014664 | 00447308 | Starbucks - 71226 | Fairfield | NJ | ZA-03227 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 17 | 2026-09-10 18:02 | 2026-09-11 08:29 | 2026-09-11 10:28 | 2026-09-11 11:08 | Dispatched |
Checked machine for any problems. Removed torn bill from lef...
Checked machine for any problems. Removed torn bill from left BA Checked for cause had Kevin test BA.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014666 | 00447323 | Starbucks - 11784 | Coral Gables | FL | UG-38234 | Smart Safe | ZONE1 | NBD | 0 | 12 | 2026-09-10 19:19 | 2026-09-10 19:19 | 2026-09-11 07:28 | Dispatched |
Hello,
This call was requested to be canceled last night ...
Hello,
This call was requested to be canceled last night at 9:51 pm, 9/10/26.
Best Regards,
Nadiezka Delgado
Customer Support Team, SME
|
Resolved - by customer | ||||
| CSDI0014671 | 00447364 | Starbucks - 2915 | Beaverton | OR | UG-38513 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-11 04:47 | 2026-09-11 05:34 | Phone Fix |
Closing case due to reported problem is out of scope for sup...
Closing case due to reported problem is out of scope for support I sent email advising closures
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014667 | 00447326 | Starbucks - 10827 | Bloomington | IN | UG-38606 | Smart Safe | ZONE2 | NBD | 1 | 2026-09-10 19:42 | 2026-09-10 20:03 | Duplicate |
Duplicate case
See case 00447014 // 00057192 // UG-38606...
Duplicate case
See case 00447014 // 00057192 // UG-38606 //
Closing this as duplicate
|
Duplicate issue | ||||||
| CSDI0014631 | 00446860 | Starbucks - 10496 | Denver | CO | UG-44125 | Smart Safe | ZONE1 | NBD | CPI | 1 | 27 | 2026-09-09 15:01 | 2026-09-09 19:00 | 2026-09-10 17:25 | 2026-09-10 18:51 | Dispatched |
Called Sesami, spoke with Juan, for new PACN. Door 1 solenoi...
Called Sesami, spoke with Juan, for new PACN. Door 1 solenoid was unreliable and would only work sporadically. Checked voltages but they?re in range. Replaced door 1 solenoid with part number listed in call notes, 201.2714.003S... but that part has a male connector and was not the correct part. Called Sesami again, spoke with Sergio, and meanwhile discovered that the correct part is 201.2714.001S. Replaced with correct part. Reattached the door 1 internal cover. Tested door 1 multiple times successfully.
|
Resolved - by field engineer with part replaced (in scope) | 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR) | |
| CSDI0014657 | 00447211 | Starbucks - 8819 | Los Angeles | CA | UG-43939 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 6 | 2026-09-10 13:55 | 2026-09-10 15:21 | 2026-09-10 19:08 | 2026-09-10 19:52 | Dispatched |
Return Tracking
1Z7611409054775962
On arrival rightside bil...
Return Tracking
1Z7611409054775962
On arrival rightside bill acceptor not taking bills, cleaned and blew out both acceptors, mei's, and csts, swapped bills acceptors to opposite same issue, replaced rightside bill acceptor, site was able to drop 10 bills on both sides, unit is up and operational ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014619 | 00446558 | Starbucks - 57544 | Bremerton | WA | ZA-02819 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 46 | 2026-09-08 21:35 | 2026-09-09 13:52 | 2026-09-10 18:58 | 2026-09-10 19:22 | Dispatched |
Arrived on site, received part from MOD. Drilled and replace...
Arrived on site, received part from MOD. Drilled and replaced new ball handle. New handle did not come with return label. Will return "part" when label is provided. Call complete, tested with site before leaving.;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014633 | 00446909 | Starbucks - 14369 | Yonkers | NY | UG-39795 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 27 | 2026-09-09 16:44 | 2026-09-09 19:21 | 2026-09-10 18:03 | 2026-09-10 19:10 | Dispatched |
Arrive to site and successfully swapped. Write bill acceptor...
Arrive to site and successfully swapped. Write bill acceptor that was constantly making noise. There was a jammed coin in the acceptor and after removing the acceptor continued to be defective. After swapping MOD Emmanuel tested and safe is up and working. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014656 | 00447207 | Starbucks - 67285 | Lacey | WA | UG-39976 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 4 | 2026-09-10 13:50 | 2026-09-10 15:25 | 2026-09-10 17:04 | 2026-09-10 17:37 | Dispatched |
Arrived on site. Received access from MOD Liz. She explained...
Arrived on site. Received access from MOD Liz. She explained they will have door 1 open, and the alarm will go off for the door being open too long all the time and that the timer isn’t long enough for them to do everything they need to do. Adjusted timer from 2 mins to 10 mins. Saved settings, opened door and waited 10 mins to confirm timer is set properly. Confirmed no other issues with safe. Call complete ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014617 | 00446550 | Starbucks - 51630 | Rialto | CA | ZA-04617 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 46 | 2026-09-08 19:35 | 2026-09-09 13:35 | 2026-09-10 14:03 | 2026-09-10 17:00 | Dispatched |
Found safe in service with liquid spilled on screen and prin...
Found safe in service with liquid spilled on screen and printer. Cleaned and calibrated screen and tested without any issues. Cleaned and reseated connections on printer amd tested without any issues. Cleaned BNFs and found coins on both but the left one jas the actuator in the up position, attempted to fix but issues remain
Called G4S and spoke with Donald who directed me NOT to replace board since it is a hardware and not software issues. He directed me to call Sesami and order a new BNF. Calles Sesami and spoke with Troy who only authorized me to replace the printer due to intermittent issues and he will reach out to Starbucks with a quote for the BNF since it was abused. He directed me to close the call and a new call will be open once Starbucks approved the BNF replacement.
Uses part 644-0132-402R return tracking 454761104206060. Not used parts 633-0020-007S and 210-0510-001R return tracking 454761104206060.;
|
Resolved - by field engineer with part replaced (in scope) |
210-0510-001R (PCB CONTROL PANEL RECONDITIONED (NON CUSTOMER...
210-0510-001R (PCB CONTROL PANEL RECONDITIONED (NON CUSTOMER SPECIFIC) (S-4)), 633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB), 644-0132-402R (PRINTER KFI)
|
|
| CSDI0014542 | 00445486 | Starbucks - 8689 | Bloomington | IL | UG-39634 | Smart Safe | ZONE3 | NBD | Burroughs | 1 | 146 | 2026-09-04 14:51 | 2026-09-04 16:00 | 2026-09-10 15:22 | 2026-09-10 16:29 | Dispatched |
Arrived onsite and replaced right side bill acceptor. The ol...
Arrived onsite and replaced right side bill acceptor. The old one had coffee beans inside. Tested with Del the manager and site is operational ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014632 | 00446867 | Starbucks - 9940 | Sequim | WA | ZA-04342 | Smart Safe | ZONE2 | NBD | Burroughs | 1 | 23 | 2026-09-09 15:18 | 2026-09-09 18:15 | 2026-09-10 14:17 | 2026-09-10 14:31 | Dispatched |
Arrived on site. Received access from MOD Savannah. She told...
Arrived on site. Received access from MOD Savannah. She told me left acceptor isn’t working. Removed acceptor found a dime jammed in acceptor. Showed site how to remove acceptor tongue as they didn’t know how to. Ended up replacing acceptor as the one installed was pretty worn. Tested new acceptor no issues. Call complete ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014624 | 00446751 | Starbucks - 54505 | Manhattan | KS | UG-45202 | Smart Safe | ZONE3 | NBD | Burroughs | 1 | 27 | 2026-09-09 11:49 | 2026-09-09 18:01 | 2026-09-10 13:29 | 2026-09-10 14:06 | Dispatched |
Arrived to site. Found safe with both acceptors blinking gre...
Arrived to site. Found safe with both acceptors blinking green. Checked voltage to mei board (23.99V measured). Raised voltage on left power supply via potentiometer (24.15V measured). Checked coltages to control panel pcb. All good. Turned safe off for 30 seconds. Turned safe on. Cleaned ba 1 thoroughly. MOD, Carsen, tested safe. He was able to make a drop without issue. Not using acceptor sent from Sesami. Machine uao;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014641 | 00446951 | Starbucks - 9308 | Levittown | NY | UG-39879 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 18 | 2026-09-09 19:24 | 2026-09-09 21:03 | 2026-09-10 13:23 | 2026-09-10 13:46 | Dispatched | Dime was removed The ba was tested & is operable ; | Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014653 | 00447184 | Starbucks - 23645 | City of Industry | CA | UG-43564 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-10 13:06 | 2026-09-10 13:37 | Phone Fix |
Good Afternoon,
We were able to contact the site, and the...
Good Afternoon,
We were able to contact the site, and the issue was identified as a broken Bill Tray.
Bill trays are consumable items.
Ticket will be closed.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014615 | 00446542 | Starbucks - 29678 | Lakewood | CO | UG-44008 | Smart Safe | ZONE1 | NBD | CPI | 1 | 42 | 2026-09-08 19:15 | 2026-09-08 22:16 | 2026-09-10 12:00 | 2026-09-10 13:13 | Dispatched |
Was told by sites manager that door was having issues lockin...
Was told by sites manager that door was having issues locking as well with bad handle ball, after inspecting locking mechanism, I found that locking mechanism was missing hardware and needed adjustments, after doing so and installing new ball handle I tested with customer, safe working fine
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014634 | 00446914 | Starbucks - 60331 | Dallas | TX | ZA-03067 | Smart Safe | ZONE1 | NBD | CPI | 1 | 19 | 2026-09-09 16:51 | 2026-09-09 19:46 | 2026-09-10 10:51 | 2026-09-10 11:59 | Dispatched |
1527679458 on arrival the customer reported a broken handle....
1527679458 on arrival the customer reported a broken handle. I removed the locking plate and attempted to cut a slit so I could unscrew the broke part. That did not work, i drilled out the broken handle and replaced it with a new one. I tested woth MoD to emsure all was in good order. Unit is testing great.
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014608 | 00446468 | Starbucks - 13742 | Mesa | AZ | UG-43983 | Smart Safe | ZONE1 | NBD | Burroughs | 3 | 31 | 2026-09-08 14:57 | 2026-09-08 17:36 | 2026-09-08 23:46 | 2026-09-09 21:34 | Dispatched |
On site doors close and business is close after hours;
On ...
On site doors close and business is close after hours;
On site doors close and business is close after hours;
On site open bottom drew rail damage called sesami talked to Mark sending rails for bottom drew.;
On site open bottom drew rail damage called sesami talked to Mark sending rails for bottom drew.;
On site open bottom drew rail damage called sesami talked to Mark sending rails for bottom drew.;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014635 | 00446923 | Starbucks - 8762 | Emporia | KS | UG-45171 | Smart Safe | ZONE3 | NBD | 0 | 2026-09-09 17:07 | 2026-09-09 17:49 | Phone Fix |
This issue is regarding manager accounts which is out of Ses...
This issue is regarding manager accounts which is out of Sesami's scope.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014618 | 00446555 | Starbucks - 24502 | Del Mar | CA | UG-43733 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 21 | 2026-09-08 20:31 | 2026-09-09 11:56 | 2026-09-09 16:41 | 2026-09-09 17:31 | Dispatched |
Upon arrival store manager Miss. Shantal let me worked on he...
Upon arrival store manager Miss. Shantal let me worked on her safe, replaced printer, let Miss. Shantal printed report good. ;
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402S (PRINTER KFI INTEGRATED (BUILT-IN) SERIES 4) | |
| CSDI0014574 | 00446506 | Starbucks - 5831 | Banning | CA | UG-43525 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 24 | 2026-09-08 16:51 | 2026-09-08 17:39 | 2026-09-09 15:50 | 2026-09-09 16:54 | Dispatched |
Replaced Modem, Spoke to Daniel of G4S , did a series of Sa...
Replaced Modem, Spoke to Daniel of G4S , did a series of Safe Communication test ,all passed , verified safe is online . Modem return tracking 792724972283. GVILLASEÑOR ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014630 | 00446855 | Starbucks - 27304 | Fresno | CA | UG-43698 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-09 14:50 | 2026-09-09 15:18 | Phone Fix |
Service was requested for a part that is considered a consum...
Service was requested for a part that is considered a consumable item.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014583 | 00446066 | Starbucks - 10564 | Durham | NC | UG-38280 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 49 | 2026-09-07 13:15 | 2026-09-07 13:47 | 2026-09-07 15:27 | 2026-09-09 14:10 | Dispatched |
The till storage vault door plastic handle broken upon arriv...
The till storage vault door plastic handle broken upon arrival. Contacted SESAMI tech support and a new handle will be send out tomorrow for an ETA of 09.09.2026. ;
The till storage vault door plastic handle broken upon arrival. Contacted SESAMI tech support and a new handle will be send out tomorrow for an ETA of 09.09.2026. ;
Replaced the broken till vault door plastic handle and tested good. The smartsafe is in service with no fault. Sent the small plastic piece of the broken vault door handle, what is left of it.;
|
Resolved - by field engineer with part replaced (in scope) | 205-7842-001S (PLASTIC HANDLE AUTOLOCK SHORT) | |
| CSDI0014591 | 00446148 | Starbucks - 18858 | Brooklyn | NY | UG-39792 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 43 | 2026-09-07 19:30 | 2026-09-07 20:38 | 2026-09-08 11:49 | 2026-09-09 14:02 | Dispatched |
9/8/26: Arrived on-site spoke to store manager MOD, Leanne a...
9/8/26: Arrived on-site spoke to store manager MOD, Leanne and Ebony. I troubleshooted the SmartSafe Right Side Bill Acceptor #2 and it is failed even on swapping etc, also the printer is inoperable as well. I spoke to Perry at Sesami Tidel and a new BA2 and printer is on order....I updated Leanne as well.;
9/8/26: Arrived on-site spoke to store manager MOD, Leanne and Ebony. I troubleshooted the SmartSafe Right Side Bill Acceptor #2 and it is failed even on swapping etc, also the printer is inoperable as well. I spoke to Perry at Sesami Tidel and a new BA2 and printer is on order....I updated Leanne as well.;
9/9/26: Arrived on-site spoke to both store managers Leanne and Ebony, replaced Right Side BA2 and also pri ter tested with Ebony all pass.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0132-402S (PRINTER KFI INTEGRATED (BUILT-IN) SERIES 4)
|
|
| CSDI0014626 | 00446803 | Starbucks - 2650 | St. Charles | IL | UG-41089 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-09 13:15 | 2026-09-09 13:40 | Phone Fix | Resolved over phone | Resolved - by 3rd party second line support | ||||||
| CSDI0014516 | 00445244 | Starbucks - 55077 | Rocky Point | NY | UG-39641 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 136 | 2026-09-03 21:01 | 2026-09-04 10:14 | 2026-09-08 10:41 | 2026-09-09 13:35 | Dispatched |
Reach out to tidel and deposita before arrival and was asked...
Reach out to tidel and deposita before arrival and was asked to go on site to access the issue. At arrival Met with MOD Meg who said courier has been coming without a key. Tech tested and I key works. Spoke with Jermaine from tidel assurring settings are correct for courier. Mod said courier his coming tomorrow...typically around 12. Tech will return then. ;
Reach out to tidel and deposita before arrival and was asked to go on site to access the issue. At arrival Met with MOD Meg who said courier has been coming without a key. Tech tested and I key works. Spoke with Jermaine from tidel assurring settings are correct for courier. Mod said courier his coming tomorrow...typically around 12. Tech will return then. ;
Met with MOD Meg. Met with Courier Marvin from "Safe and Sound" also spoke with his superior Martha. Gave courier safe access he then emptied cassettes. Customer can now make deposits. Tech closing call;
|
Resolved - by field engineer with part replaced (in scope) | 644-0134-001S (i-BUTTON READER/SOCKET) | |
| CSDI0014573 | 00445887 | Starbucks - 62242 | Midland | TX | ZA-03056 | Smart Safe | ZONE1 | NBD | CPI | 1 | 70 | 2026-09-06 15:15 | 2026-09-06 17:35 | 2026-09-09 12:45 | 2026-09-09 13:10 | Dispatched |
Upon arrival spoke with MOD she pulled out the ball handle l...
Upon arrival spoke with MOD she pulled out the ball handle looks like the last it was drilled out they took all threads off i used JB weld to weld the ball handle in place worked well since we not get the locking plate had customer test with no issues
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014611 | 00446487 | Starbucks - 55348 | Scotts Valley | CA | UG-44005 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 21 | 2026-09-08 15:58 | 2026-09-08 18:15 | 2026-09-09 12:37 | 2026-09-09 12:56 | Dispatched |
Arrived on site, started troubleshooting issues with Bv. Bv ...
Arrived on site, started troubleshooting issues with Bv. Bv had a coin jammed. After clearing Bv, it wad still not communicating. Replaced Bv with the new one sent out and tested with MOD. Bv1 is now functioning without any issues. Safe is up and running.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014621 | 00446710 | Starbucks - 8782 | Hot Springs | AR | UG-45184 | Smart Safe | ZONE2 | NBD | 3 | 2026-09-09 10:44 | 2026-09-09 13:02 | Phone Fix | Resolved over phone. | Resolved - by 3rd party second line support | ||||||
| CSDI0014625 | 00446768 | Starbucks - 10065 | Tampa | FL | UG-38137 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-09 12:21 | 2026-09-09 12:51 | Phone Fix |
This issue is regarding manager accounts which is out of Ses...
This issue is regarding manager accounts which is out of Sesami's scope. Advised calling Deposita directly.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014593 | 00446167 | Starbucks - 50181 | Big Spring | TX | ZA-02997 | Smart Safe | ZONE1 | NBD | CPI | 1 | 34 | 2026-09-07 23:26 | 2026-09-08 13:21 | 2026-09-09 09:19 | 2026-09-09 09:43 | Dispatched |
Upon arrival spoke with MOD said the right bill acceptor was...
Upon arrival spoke with MOD said the right bill acceptor was not working had her open the maintenance door and removed both bill acceptors and ckeaned them and found a penny in the right one after cleaning the acceptors and reinstalling them had customer test the safe both worked fine
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014559 | 00445698 | Starbucks - 10509 | Louisville | KY | UG-38700 | Smart Safe | ZONE1 | NBD | CPI | 1 | 90 | 2026-09-05 14:02 | 2026-09-05 15:13 | 2026-09-09 08:43 | 2026-09-09 08:56 | Dispatched |
Called tidel asked Tamica if i was allowed to reset the time...
Called tidel asked Tamica if i was allowed to reset the time on the safe from 10 minutes back to two minutes. I was informed that the delay can olny be changed by the safe owner. Explained this tonthe manager on duty, Rachel. She will call deposita to correct the issue.
Pacn 0214 43 7693
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014620 | 00446571 | Starbucks - 11283 | Marion | OH | UG-38725 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-09 03:54 | 2026-09-09 04:30 | Phone Fix |
Issue: Safe – Display Showing Lines in Different Colors
T...
Issue: Safe – Display Showing Lines in Different Colors
Troubleshooting Steps: I called the site and requested troubleshooting. I had the CSM perform a power cycle and reboot the unit. After the reboot, the unit came back online and the error cleared. The CSM was able to log in and successfully complete a transaction.
Result: Issue fixed. Unit is back online and operating normally.
|
Resolved - by 3rd party second line support | ||||||
| CSDI0014613 | 00446490 | Starbucks - 66054 | San Jose | CA | ZA-04601 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 5 | 2026-09-08 16:04 | 2026-09-08 18:23 | 2026-09-08 21:20 | 2026-09-08 21:44 | Dispatched |
Prior to arrival had to pick up part at Hayward FSL. Around ...
Prior to arrival had to pick up part at Hayward FSL. Around a two our commute. Arrived on site, after some troubleshooting there was issues with the cassette but after reseating the bv, Mei card, and the cassette the issues cleared. Then tested with MOD and is now working properly. Also part ordered by tidel was the incorrect part. Sending part back not needed. Safe is up and running.;
|
Resolved - by field engineer with part replaced (in scope) | 644-0106-015S (CASSETTE MEI XL HI-CAP) | |
| CSDI0014607 | 00446465 | Starbucks - 817 | New York | NY | UG-39894 | Smart Safe | ZONE1 | NBD | 0 | 5 | 2026-09-08 14:51 | 2026-09-08 14:51 | 2026-09-08 19:53 | Dispatched |
Per Deposita, quote was not approved and was advised to clos...
Per Deposita, quote was not approved and was advised to close ticket
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014595 | 00446173 | Starbucks - 8290 | Sunny Isles Beach | FL | UG-38277 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 15 | 2026-09-08 04:47 | 2026-09-08 11:14 | 2026-09-08 18:25 | 2026-09-08 19:12 | Dispatched |
At arrival found 2 issues one BV was damaged nit repairable ...
At arrival found 2 issues one BV was damaged nit repairable replaced as need the other one was performed maintenance
Had Manager test deposits successfully ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014603 | 00446414 | Starbucks - 9776 | Broomall | PA | UG-39790 | Smart Safe | ZONE1 | NBD | 3 | 2026-09-08 13:21 | 2026-09-08 16:03 | Phone Fix |
This issue is related to courier account management, which i...
This issue is related to courier account management, which is outside Sesami's scope of support.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014600 | 00446338 | Starbucks - 24661 | Sioux City | IA | UG-38880 | Smart Safe | ZONE2 | NBD | 0 | 2026-09-08 11:21 | 2026-09-08 11:43 | Phone Fix | cx added account.. ticket closed | Resolved - by customer | ||||||
| CSDI0014567 | 00445761 | Starbucks - 9290 | Winchester | CA | UG-43718 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 45 | 2026-09-05 23:20 | 2026-09-06 16:57 | 2026-09-07 14:34 | 2026-09-07 20:01 | Dispatched |
Pickup Call out part from UPSFSL MIRA LOMA. Replaced right s...
Pickup Call out part from UPSFSL MIRA LOMA. Replaced right side BV ,tested both ,left also faulty, it follows when I move to other side ,ordered placed to Dominic of SESAMI, Debrief MoD Brad. Left side Faulty. GVILLASEÑOR ;
Pickup Call out part from UPSFSL MIRA LOMA. Replaced right side BV ,tested both ,left also faulty, it follows when I move to other side ,ordered placed to Dominic of SESAMI, Debrief MoD Brad. Left side Faulty. GVILLASEÑOR ;
On arrival proceed to replaced the bill acceptor due to malfunctions. Once the part has been replaced bring the safe in service, Kelvin the assistant manager tests the safe, all tests successfully completed ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014585 | 00446098 | Starbucks - 63221 | Roanoke | VA | UG-38347 | Smart Safe | ZONE3 | NBD | 0 | 4 | 2026-09-07 14:30 | 2026-09-07 14:30 | 2026-09-07 18:04 | Dispatched |
Per Deposita, quote was not approved and was advised to clos...
Per Deposita, quote was not approved and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014584 | 00446089 | Starbucks - 8982 | Castle Pines | CO | UG-38498 | Smart Safe | ZONE1 | NBD | 0 | 4 | 2026-09-07 14:12 | 2026-09-07 14:12 | 2026-09-07 18:03 | Dispatched |
Per Deposita, quote was not approved and was advised to clos...
Per Deposita, quote was not approved and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014561 | 00445739 | Starbucks - 49389 | Rancho Cordova | CA | UG-44012 | Smart Safe | ZONE1 | NBD | Burroughs | 4 | 48 | 2026-09-05 17:19 | 2026-09-05 18:13 | 2026-09-05 20:23 | 2026-09-07 17:35 | Dispatched |
After calling the UPS 1-800 number provided in the call log,...
After calling the UPS 1-800 number provided in the call log, I was informed by Leticia that the estimated wait time for an after-hours representative to arrive and provide site access was approximately one hour. Due to the extended response time and it already being approximately 6:30 PM, the service call will need to be forwarded to tomorrow for completion.;
After calling the UPS 1-800 number provided in the call log, I was informed by Leticia that the estimated wait time for an after-hours representative to arrive and provide site access was approximately one hour. Due to the extended response time and it already being approximately 6:30 PM, the service call will need to be forwarded to tomorrow for completion.;
See previous notes;
See previous notes;
Starbucks was closed by the time I even got back from Stockton driving through;
Starbucks was closed by the time I even got back from Stockton driving through;
As previously documented, due to the Sacramento FSL being closed, I scheduled an after-hours parts meet with Alan from UPS and waited approximately one hour for his arrival. After obtaining the required parts, I proceeded to the site at 4010 Sunset Boulevard in Rancho Cordova, California, where I met with the on-shift manager, Keyana. I contacted Tidel support and spoke with Tyrell to obtain the PACN code and gain access to the safe. Prior to replacing any components, I asked Keyana to describe the reported issue. She stated that the touchscreen "basically had a mind of its own" and would operate intermittently. During inspection, I observed visible discoloration in the lower-left portion of the display. I performed voltage checks at the PCB to determine whether the issue could be related to unstable power delivery. The measured rails were stable at 5.1 VDC and 24.2 VDC with no observed fluctuations. Based on the stable voltage readings and absence of evidence indicating a PCB failure, I determined that PCB replacement was not warranted and replaced only the touchscreen/display assembly. Following installation, I had Keyana perform functional testing by logging into the safe and navigating through the menus to verify proper touchscreen response and operation. Keyana also mentioned that the bill acceptors would occasionally experience issues. I showed her the bill-reading optical sensors behind the clear glass/plastic surfaces and demonstrated the proper cleaning procedure using a Q-tip to help prevent acceptance issues caused by contamination or debris.;
|
Resolved - by field engineer with part replaced (in scope) |
210-0510-107S (PCB CONTROL PANEL (G4S) (S-4)), 633-0020-007S...
210-0510-107S (PCB CONTROL PANEL (G4S) (S-4)), 633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB)
|
|
| CSDI0014572 | 00445885 | Starbucks - 10239 | Elgin | IL | UG-40685 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 26 | 2026-09-06 15:01 | 2026-09-06 17:14 | 2026-09-07 16:58 | 2026-09-07 17:31 | Dispatched |
Right BA had a bill jam that they couldn't remove. Had Nicho...
Right BA had a bill jam that they couldn't remove. Had Nichole open the maintenance door and found pieces of a bill inside along with a dime. Removed all debris and cleaned both BAs. Nichole tested a bill drop in both BAs and both passed. Safe is up and running. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014577 | 00445907 | Starbucks - 25955 | Highland | CA | ZA-04659 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 20 | 2026-09-06 21:20 | 2026-09-07 12:57 | 2026-09-07 16:57 | 2026-09-07 17:26 | Dispatched |
After picking up parts from ups fsl Mira Loma I headed to si...
After picking up parts from ups fsl Mira Loma I headed to site once on site poc Hannah gave me access to safe i noticed the screen was cracked printer had lights on .I replaced screen and once I power unit up it came into service poc Hannah tested unit without any issues
Part return tracking provided by sesami
1Z7611409054185466;
|
Resolved - by field engineer with part replaced (in scope) |
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH ...
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB)
|
|
| CSDI0014588 | 00446117 | Starbucks - 11027 | Moreno Valley | CA | ZA-04651 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-07 16:07 | 2026-09-07 16:17 | Phone Fix |
This issue is regarding manager accounts which is out of Ses...
This issue is regarding manager accounts which is out of Sesami's scope.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014566 | 00445759 | Starbucks - 19258 | Houston | TX | ZA-04377 | Smart Safe | ZONE1 | NBD | CPI | 2 | 154 | 2026-09-05 23:04 | 2026-09-06 16:49 | 2026-09-07 08:30 | 2026-09-12 09:25 | Dispatched |
991 Z@C@Rias
When i came on site the mod said the ba wasn?t...
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
991 Z@C@Rias
When i came on site the mod said the ba wasn?t working. I did an inspection and found that it had syrup on both ba. Thats why it wasn?t working but it damaged both. I called Tidel to order the parts spoke with Jacky
Its on other call
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014529 | 00445267 | Starbucks - 23602 | Yonkers | NY | UG-38877 | Smart Safe | ZONE1 | NBD | Burroughs | 3 | 80 | 2026-09-04 06:42 | 2026-09-04 09:25 | 2026-09-04 15:55 | 2026-09-07 14:47 | Dispatched |
Picked up solenoid prior to arrival once onsite found drop v...
Picked up solenoid prior to arrival once onsite found drop vault solenoid is working. The issue is the drop vault sensor. Richard from Tidel support said he would need to get approval from Starbucks before sending drop vault door sensor. Will return once parts are sent out.;
Picked up solenoid prior to arrival once onsite found drop vault solenoid is working. The issue is the drop vault sensor. Richard from Tidel support said he would need to get approval from Starbucks before sending drop vault door sensor. Will return once parts are sent out.;
Picking up vice grip pliers, will return.;
Picking up vice grip pliers, will return.;
Picked up parts from FSL prior to arriving. Once onsite I successfully installed solenoid and door sensor. Drop vault is successfully working after multiple test.;
|
Resolved - by field engineer with part replaced (in scope) |
201-2714-003S (Do Not Use - SOLENOID BILL ACCEPTOR & MAINTEN...
201-2714-003S (Do Not Use - SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR), 632-0012-010S (SENSOR KIT VAULT DOORS (2 PER))
|
|
| CSDI0014511 | 00444914 | Starbucks - 78566 | Salinas | CA | UG-44085 | Smart Safe | ZONE1 | NBD | Burroughs | 3 | 100 | 2026-09-03 10:15 | 2026-09-03 12:15 | 2026-09-04 17:27 | 2026-09-07 14:15 | Dispatched |
The printer feed and cut buttons do not function. Checked de...
The printer feed and cut buttons do not function. Checked device status and it shows printer unspecified failure. I also checked the device power supplies and they are both outputting to spec. Access back of printer to remove and reinstall power and data cable to improve electrical connection and reinitialize the safe but it still does not feed or cut, will order new printer.;
The printer feed and cut buttons do not function. Checked device status and it shows printer unspecified failure. I also checked the device power supplies and they are both outputting to spec. Access back of printer to remove and reinstall power and data cable to improve electrical connection and reinitialize the safe but it still does not feed or cut, will order new printer.;
Called Tidel support - Brendan to order the KFI printer and it will be Courier to site and available for tomorrow - Monday install.;
Called Tidel support - Brendan to order the KFI printer and it will be Courier to site and available for tomorrow - Monday install.;
Upon arrival, check device power supply voltages and confirm they are outputting to specification. The manager informed me that this safe came from another location and was recently installed here and hasn't been working properly. I checked the device status menu and it showed one of the bill validators unspecific failure and it showed the printer not communicating . When I began the process of removing the printer that was tested last time, I saw that the power wire was loose-coming out of the connector that feeds into the printer and I recrimped it to the Brass fitting that plugs into the connector body and plugged it back into the printer. The printer then powered on and I went into device status again and it now shows printer ready. I then navigated to the Diagnostics menu and perform test print and all characters were printing perfect. I then removed and thoroughly cleaned inside of both Bill validators and remove the roller assembly and blue out lots of dust from the throat area and lint and then reassemble them and reinstalled them and they both initialized properly and now device status shows both Bill validators ready. I observed the manager testing post bill validators with several notes, successful. Being that this is a new safe install and the manager said he was not briefed on its correct operation, I spent some time showing him the various menus items and printed a current content report and showed him how to add Clerks into the safe with name and pin number. I was fortunate to spot that the brass cable connector was coming out of the plug that feeds into the printer and did not have to use the new printer part. Customer safe is now operating properly and back in service.;
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402S (PRINTER KFI INTEGRATED (BUILT-IN) SERIES 4) | |
| CSDI0014547 | 00445527 | Starbucks - 22164 | Hobbs | NM | UG-39832 | Smart Safe | ZONE4 | NBD | Burroughs | 1 | 71 | 2026-09-04 16:28 | 2026-09-04 18:14 | 2026-09-07 12:20 | 2026-09-07 15:12 | Dispatched |
Upon arrival , I got in contact with manager with a smart sa...
Upon arrival , I got in contact with manager with a smart safe login.
I opened and accessed the BAs.
I begin troubleshooting the issue. I pm the BAs I pm the device
I test the BAs . Successfull operations.
Smart safe up and operational.
;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014564 | 00445753 | Starbucks - 50835 | Westlake | TX | ZA-04382 | Smart Safe | ZONE1 | NBD | CPI | 1 | 40 | 2026-09-05 20:36 | 2026-09-06 16:43 | 2026-09-07 10:53 | 2026-09-07 12:17 | Dispatched |
Upon arrival safe with drop vault broken handle. Accessed sa...
Upon arrival safe with drop vault broken handle. Accessed safe with packing coded and when trying to open the safe noticed solenoid not acting. Smacked door with mallet and managed to open the door. Removed placed and extracted remaining thread intalled plate back amd installed handle. Replaced solenoid and tested door several times with no issues. Customer tested good.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014578 | 00445917 | Starbucks - 5774 | Long Beach | CA | UG-43580 | Smart Safe | ZONE1 | NBD | 0 | 13 | 2026-09-06 22:08 | 2026-09-06 22:08 | 2026-09-07 11:18 | Dispatched |
Per Deposita, ticket was cancelled and was advised to close ...
Per Deposita, ticket was cancelled and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014579 | 00445918 | Starbucks - 5774 | Long Beach | CA | UG-43580 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-06 22:08 | 2026-09-06 23:20 | Duplicate | Duplicate of 00445917 | Duplicate issue | ||||||
| CSDI0014575 | 00445888 | Starbucks - 8768 | Reno | NV | UG-45718 | Smart Safe | ZONE1 | NBD | 2 | 2026-09-06 15:37 | 2026-09-06 17:42 | Phone Fix | Per customer, the issue has been resolved. | Resolved - by customer | ||||||
| CSDI0014551 | 00445599 | Starbucks - 6967 | Scottsdale | AZ | UG-43977 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 35 | 2026-09-05 06:46 | 2026-09-05 10:42 | 2026-09-06 17:13 | 2026-09-06 17:35 | Dispatched |
Arrived onsite and spoke to Christian (assistant on duty). H...
Arrived onsite and spoke to Christian (assistant on duty). He was not aware of the ticket. He did some digging and found that an employee named Kimberly (who was a visiting associate) , put the ticket in unnecessarily. They tried to cancel the order, but It did not reach is in time. No parts associated with this order. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014568 | 00445770 | Starbucks - 6258 | McKinney | TX | ZA-03123 | Smart Safe | ZONE1 | NBD | 0 | 12 | 2026-09-06 04:58 | 2026-09-06 04:58 | 2026-09-06 16:40 | Dispatched | Per Deposita's request, closing ticket | Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014563 | 00445747 | Starbucks - 8321 | Baton Rouge | LA | ZA-04536 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 21 | 2026-09-05 18:36 | 2026-09-05 21:06 | 2026-09-06 15:15 | 2026-09-06 15:39 | Dispatched |
Arrived on site and checked in with mod Christopher. Called ...
Arrived on site and checked in with mod Christopher. Called into sesami and gained new pacn. Deep cleaned ba2 and found that it was stuck in a constant initialization loop. Swapped and error followed. Replaced BA2 and tested successfully. ba1 worked intermittently. Deep cleaned with cleaning card and blew out with blower and tested successfully. Return tracking for used ba is 1Z7611409052454151. UPS location is closed on sunday so part will be dropped off monday morning. Unit is up and open.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014535 | 00445410 | Starbucks - 21655 | Fair Lawn | NJ | UG-39678 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 50 | 2026-09-04 12:03 | 2026-09-04 13:44 | 2026-09-06 13:42 | 2026-09-06 14:52 | Dispatched |
Jam In Bill Acceptor
Clean Acceptor & Remove any jams
Cl...
Jam In Bill Acceptor
Clean Acceptor & Remove any jams
Cleaned bill acceptors and removed jammed foreign object from left bill acceptor. Tested both bill acceptors with customer. Both tested good. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014537 | 00445450 | Starbucks - 7660 | Carnot-Moon | PA | UG-39594 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 47 | 2026-09-04 13:35 | 2026-09-04 19:44 | 2026-09-06 10:39 | 2026-09-06 12:23 | Dispatched |
right bill acceptor grinding
Replace the Bill Acceptor
Test...
right bill acceptor grinding
Replace the Bill Acceptor
Test The Bill Acceptor
inspect/clean acceptor
check for jam
When I arrived i cleaned both acceptors. Reseated imei cards. Cleaned cassettes. Right side still shows jammed. Swapped bv and error moved with bv. Swapped back and replaced. Reset odometers. Manager successfully deposited bills in both acceptors. Safe up and open.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014569 | 00445838 | Starbucks - 7781 | New York | NY | UG-39768 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-06 11:33 | 2026-09-06 11:38 | Phone Fix |
Called POC twice but no one answered.
Store needs ne...
Called POC twice but no one answered.
Store needs new PIN for manager.
Email sent to Deposita for user management assistance.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014513 | 00445125 | Starbucks - 71319 | Wading River | NY | UG-38290 | Smart Safe | ZONE2 | NBD | Burroughs | 1 | 69 | 2026-09-03 14:37 | 2026-09-03 15:42 | 2026-09-06 10:44 | 2026-09-06 11:28 | Dispatched |
Met with MOD Nick. I key no working at arrival. Tech reboot...
Met with MOD Nick. I key no working at arrival. Tech rebooted safe and reseated connections which resolved issue. Tech tested i key successfully. Safe is operational ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014562 | 00445740 | Starbucks - 53861 | Austin | TX | ZA-04226 | Smart Safe | ZONE1 | NBD | CPI | 1 | 18 | 2026-09-05 17:23 | 2026-09-05 18:21 | 2026-09-06 11:02 | 2026-09-06 11:06 | Dispatched |
Silva859. Ba failure
Called to make sure what the real pr...
Silva859. Ba failure
Called to make sure what the real problem was, and spoke to Foster, 2nd in command, head mgr wasnt present, he said main issue was drop vault, Not BA! And he told me he just opened drop vault prior to my phone call, and both BAs work! Case closed no need to waste company gas for nothing.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014556 | 00445686 | Starbucks - 6619 | Alexandria | VA | ZA-03162 | Smart Safe | ZONE2 | NBD | CPI | 1 | 20 | 2026-09-05 13:16 | 2026-09-05 15:09 | 2026-09-06 08:35 | 2026-09-06 09:27 | Dispatched |
onsite spoke w MOD re Right acceptor had creamer spilled ins...
onsite spoke w MOD re Right acceptor had creamer spilled inside and not working issue confirmed via system behavior replaced 845.z206.r0 then logged into unit ran baseline checks device status diagnostics voltage test all ok verified vault doors closed secure no safety issues checked connections and overall condition confirmed system integrity had customer test acceptors successfully issues resolved to customer satisfaction closing call av925
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014555 | 00445675 | Starbucks - 10413 | Houston | TX | ZA-04319 | Smart Safe | ZONE1 | NBD | CPI | 1 | 20 | 2026-09-05 12:58 | 2026-09-05 14:26 | 2026-09-06 08:06 | 2026-09-06 08:17 | Dispatched |
991 Z@C@R1@S
Problem
Right BA
Solved
I arrived at the si...
991 Z@C@R1@S
Problem
Right BA
Solved
I arrived at the site and had a conversation with the manager. During our discussion, she mentioned that there was a piece of a bill stuck in the note feeder. I conducted a thorough inspection and located the half bill she referred to. Following this, I provided her with training on how to remove paper jams effectively in the machine, and she successfully demonstrated her ability to perform the task.
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014565 | 00445754 | Starbucks - 54771 | Bayside | NY | UG-39786 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-05 20:37 | 2026-09-05 20:53 | Phone Fix |
the penny was in the rollers and we got the penny out with t...
the penny was in the rollers and we got the penny out with the BA initializing and not having a bill jam error.
|
Resolved - by 3rd party second line support | ||||||
| CSDI0014550 | 00445573 | Starbucks - 53829 | Denver | CO | UG-44113 | Smart Safe | ZONE1 | NBD | CPI | 1 | 23 | 2026-09-04 20:26 | 2026-09-05 11:29 | 2026-09-05 18:40 | 2026-09-05 19:10 | Dispatched |
Did maintenance to both bill acceptor assemblies, had to rep...
Did maintenance to both bill acceptor assemblies, had to replace bad BNF on right side, tested with customer, safe working fine
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014560 | 00445730 | Starbucks - 6208 | San Antonio | TX | ZA-03057 | Smart Safe | ZONE1 | NBD | 3 | 2026-09-05 16:34 | 2026-09-05 19:19 | Phone Fix |
Hello Sesami Team,
Approval for the referenced Work Task wa...
Hello Sesami Team,
Approval for the referenced Work Task was not received within the allotted timeframe. As a result, we are unable to proceed with the service call.
Please close the ticket accordingly.
Thank you,
Mesnayda Personna
CSC Subject Matter Expert
|
Resolved - by 3rd party second line support | ||||||
| CSDI0014501 | 00444801 | Starbucks - 61890 | Glendale | CA | UG-43644 | Smart Safe | ZONE1 | NBD | Burroughs | 3 | 72 | 2026-09-02 18:51 | 2026-09-02 19:47 | 2026-09-03 18:13 | 2026-09-05 18:08 | Dispatched |
Picked up part from warehouse
Arrived on site
Replaced BA 2...
Picked up part from warehouse
Arrived on site
Replaced BA 2
Issue persists
Called tidel and troubleshot
Concluded that BA 2 replacement is DOA
New part in route;
Picked up part from warehouse
Arrived on site
Replaced BA 2
Issue persists
Called tidel and troubleshot
Concluded that BA 2 replacement is DOA
New part in route;
I arrived and both bvs cleaned and swapped. Replaced one bv. Only one side works. If I swap it follows the issues, the side will work but not the other. Need bulk bv. Talked with Teresa at site. Then called Sesami and talked with Juan. Ordered a bulk feed bv. Replaced bv 644-0117-434r, xr167773. UPS next day air.;
I arrived and both bvs cleaned and swapped. Replaced one bv. Only one side works. If I swap it follows the issues, the side will work but not the other. Need bulk bv. Talked with Teresa at site. Then called Sesami and talked with Juan. Ordered a bulk feed bv. Replaced bv 644-0117-434r, xr167773. UPS next day air.;
Picked up from FSL 8615 Tamarack Ave. Sun Valley. Arrived onsite and was given access by Lilly MOD. I was told that R/S BV was not accepting notes. Replaced BV and had her test successfully. Both BV'S are not fully functional. Safe is up and open.
1st BV Returned by Jaime M.
XR-167773
1Z76114O0199034103
2nd BV
New Core Serial Number
XR-167249
Replaced Core Serial Number
XR-168015
Return Tracking Number 1Z7611409054559071;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014517 | 00445105 | Starbucks - 11725 | New Orleans | LA | ZA-04446 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 51 | 2026-09-03 14:22 | 2026-09-03 17:18 | 2026-09-05 16:26 | 2026-09-05 17:47 | Dispatched |
Arrived onsite and replaced ball handle with JB Weld. Will t...
Arrived onsite and replaced ball handle with JB Weld. Will take 4 to 6 hours to cure. Advised site to try not to touch it until then. Unit is up and open.;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014558 | 00445688 | Starbucks - 29863 | Mission Hills | CA | UG-43678 | Smart Safe | ZONE1 | NBD | 2 | 2026-09-05 13:38 | 2026-09-05 15:11 | Phone Fix |
Good afternoon,
I contacted the store and spoke with Eri...
Good afternoon,
I contacted the store and spoke with Eric the MOD.
The part in question is the bill acceptor tray/bulk note feeder
I provided them with information on how to order directly from Tidel/Sesami.
A dispatch is not needed
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014504 | 00444820 | Starbucks - 21800 | Los Angeles | CA | UG-43624 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 63 | 2026-09-02 22:53 | 2026-09-03 08:09 | 2026-09-04 13:49 | 2026-09-05 13:58 | Dispatched |
Arrived to site and checked in with MOD. Had to use tap n di...
Arrived to site and checked in with MOD. Had to use tap n die to put ball handle into place. Site states its hard to close door. I pulled out drawers and clean oit drop vault. Checked rails and saw significant wear on the left side. Made adjustments on left rail. Door still cant lock. Adjusted locking plate by tight ing plates. Still won't let me close the door. I called Sesami and spoke to Moon . I was transferred to Rich in tier 3. I remember the other one i worked on needed washers. I told him I remember that. I loosened the door locking plate and was able to push lock more in. I will need to go to Lowes and get washers to bump out the door. ;
Arrived to site and checked in with MOD. Had to use tap n die to put ball handle into place. Site states its hard to close door. I pulled out drawers and clean oit drop vault. Checked rails and saw significant wear on the left side. Made adjustments on left rail. Door still cant lock. Adjusted locking plate by tight ing plates. Still won't let me close the door. I called Sesami and spoke to Moon . I was transferred to Rich in tier 3. I remember the other one i worked on needed washers. I told him I remember that. I loosened the door locking plate and was able to push lock more in. I will need to go to Lowes and get washers to bump out the door. ;
I requested cover doir to be replaced as it had broken washers. I was instructed to locally source them. It took me 3 trips to Lowes. Successfully bumped out door so it didnt hit locking rails. Successfully tested door with MOD helen..;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014508 | 00444866 | Starbucks - 62820 | Bronx | NY | UG-41575 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 52 | 2026-09-03 08:40 | 2026-09-03 13:04 | 2026-09-05 11:09 | 2026-09-05 12:13 | Dispatched |
9/5/26: Arrived on-site spoke to store manager Iesha. Troubl...
9/5/26: Arrived on-site spoke to store manager Iesha. Troubleshooted the SmartSafe and needed to replace the Right Side Bill Acceptor BA2. Tested with staff on Insert Bills tests all pass.;
|
Resolved - by field engineer with part replaced (in scope) |
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH ...
633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014538 | 00445456 | Starbucks - 22307 | Houston | TX | ZA-04298 | Smart Safe | ZONE1 | NBD | CPI | 1 | 21 | 2026-09-04 13:46 | 2026-09-04 16:05 | 2026-09-05 08:54 | 2026-09-05 10:23 | Dispatched |
***TECH#196 CATO***
On site 9/5@8:55am. On arrival Door 2 wa...
***TECH#196 CATO***
On site 9/5@8:55am. On arrival Door 2 was working and the sensors were functioning as they should, however the lock bar was binding up when trying to close. I disassembled the door and found dried grease on the bushings inside. Cleaned off dried grease from bushings and relubricated. Also, the set screws that stabalize the lock bar had backed out of place, applied Loctite to screws and adjusted. Reassembled door and tested repeatedly. No parts replaced, see photos attached
|
Resolved - by field engineer with part replaced (in scope) | 632-0012-110S (SENSOR KIT VAULT DOORS (2 PER) WIDE) | |
| CSDI0014518 | 00445106 | Starbucks - 8758 | Edgewater | CO | UG-44126 | Smart Safe | ZONE1 | NBD | CPI | 1 | 44 | 2026-09-03 14:22 | 2026-09-03 20:02 | 2026-09-05 09:32 | 2026-09-05 10:14 | Dispatched |
Did maintenance to both bill acceptor assemblies, tested, ac...
Did maintenance to both bill acceptor assemblies, tested, acceptor 2 was stll not responding, replaced bad bill acceptor, tested, working fine
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014541 | 00445479 | Starbucks - 9343 | Pacific Beach | CA | ZA-04610 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 7 | 2026-09-04 14:43 | 2026-09-04 16:04 | 2026-09-04 20:00 | 2026-09-04 21:28 | Dispatched |
Upon arrival store manager Miss. Anna let me worked on her s...
Upon arrival store manager Miss. Anna let me worked on her safe, replaced printer, let Miss. Anna printed reports came out good. ;
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402R (PRINTER KFI) | |
| CSDI0014548 | 00445554 | Starbucks - 14494 | East Point | GA | UG-38068 | Smart Safe | ZONE1 | NBD | 4 | 2026-09-04 17:34 | 2026-09-04 21:21 | Phone Fix | Not approved, cancelled | Resolved - by customer | ||||||
| CSDI0014463 | 00444017 | Starbucks - 47697 | El Monte | CA | UG-43919 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 95 | 2026-08-31 21:52 | 2026-09-02 19:14 | 2026-09-04 20:20 | 2026-09-04 20:49 | Dispatched |
Took me around 2 hours to pick up part at FSL and go to site...
Took me around 2 hours to pick up part at FSL and go to site. Talked with Gen manager at site. Replaced left bv 644-0117-434r, xr164790. Tracking 1z 761 140 01 9536 5496. Tested money in ok. Ups next day air. Ups store closed at this time.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014526 | 00445249 | Starbucks - 6551 | Fremont | CA | UG-43766 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 22 | 2026-09-03 22:21 | 2026-09-04 11:50 | 2026-09-04 20:03 | 2026-09-04 20:25 | Dispatched |
Cleared jammed $20 from left note acceptor. Had mod Elliot t...
Cleared jammed $20 from left note acceptor. Had mod Elliot test cash accept after cleaning left note acceptor. Confirmed working properly.;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014522 | 00445195 | Starbucks - 9871 | Valencia | CA | UG-43836 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 28 | 2026-09-03 16:47 | 2026-09-03 19:14 | 2026-09-04 19:25 | 2026-09-04 20:10 | Dispatched |
Picked up part from FSL
Arrived onsite
Was given access by ...
Picked up part from FSL
Arrived onsite
Was given access by Aiden MOD and was informed that both BV'S were malfunctioning
Inspected bill validators and cassette
Confirmed that both BV's are malfunctioning by not accepting bills
Replaced left BV and cleaned right BV sensors
Both BV's now accept bills and are fully functional
System is now up and open
New Core Serial Number XR-169011
Replaced Core Serial Number XR-148343
Return Tracking Number 1Z7611409052024455;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014531 | 00445272 | Starbucks - 22003 | Portland | OR | ZA-02976 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 37 | 2026-09-04 06:58 | 2026-09-04 14:06 | 2026-09-05 18:56 | 2026-09-05 19:24 | Dispatched |
Arrived on site, manager disclosed issue had been resolved p...
Arrived on site, manager disclosed issue had been resolved prior to arrival. Tested unit drop vault solenoid just to verify, confirmed. Safe in working condition. Informed from manager that ticket was meant to be closed prior to arrival. Confirmed status/condition of safe, issue resolved. Closing out ticket;
|
Resolved - by customer |
205-4086-001S (SOLENOID ASSY W/ ANTI-THEFT), 210-0510-107R (...
205-4086-001S (SOLENOID ASSY W/ ANTI-THEFT), 210-0510-107R (PCB CONTROL PANEL RECONDITIONED (G4S)), 642-0002-101S (POWER SUPPLY SERIES 4 RIGHT SIDE & S5)
|
|
| CSDI0014486 | 00444419 | Starbucks - 880 | South Brookline | MA | UG-41529 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 67 | 2026-09-01 20:52 | 2026-09-02 11:02 | 2026-09-03 10:11 | 2026-09-04 15:37 | Dispatched |
Arrived on site.Both BA unavailable. 24 v power to left supp...
Arrived on site.Both BA unavailable. 24 v power to left supply and both Mei cards have power. Liquid has appeared to damage the control panel. Left bill acceptor had a dime inside that damage a piece of Grey plastic. Unsure if this acceptor will work. Contacted sesami for control panel and a bill acceptor which they stated they will need to email deposita for part confirmation. Returning when parts available. Sesami did state that deposita approved for 2 bill acceptors to be replaced but the control panel may be damaged due to liquid. Confirmed that sesami stated deposita only approved for the 2 bill acceptors even though a control panel may be needed. ;
Arrived on site.Both BA unavailable. 24 v power to left supply and both Mei cards have power. Liquid has appeared to damage the control panel. Left bill acceptor had a dime inside that damage a piece of Grey plastic. Unsure if this acceptor will work. Contacted sesami for control panel and a bill acceptor which they stated they will need to email deposita for part confirmation. Returning when parts available. Sesami did state that deposita approved for 2 bill acceptors to be replaced but the control panel may be damaged due to liquid. Confirmed that sesami stated deposita only approved for the 2 bill acceptors even though a control panel may be needed. ;
Arrived on-site and checked in with MOD Adam. Delayed approx. 20 minutes waiting for parts. Contacted Sesami for a PACN code and accessed the acceptor maintenance door. Found and cleared a bill jam and coffee bean in BA2, then moved BA2 to the left side. Replaced faulty BA1 with a new acceptor. Completed successful test deposits on both sides with MOD Adam. Used only one of the new BAs, Unit is up and operational.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014512 | 00444950 | Starbucks - 67349 | Rosenberg | TX | ZA-04322 | Smart Safe | ZONE1 | NBD | CPI | 1 | 27 | 2026-09-03 10:56 | 2026-09-03 12:57 | 2026-09-04 12:55 | 2026-09-04 13:37 | Dispatched |
***TECH#196 CATO***
On site 9/4@12:55pm. On arrival Door 2 w...
***TECH#196 CATO***
On site 9/4@12:55pm. On arrival Door 2 would not open. Found the cable had pulled loose from the distribution PCB. I created some extra salck in the cable and plugged it back in. Tested all doors and showed Alexis how to clear jams in the acceptors, she is new to this store and had some questions. No parts replaced, see photos attached
|
Resolved - by field engineer with part replaced (in scope) | 201-2714-001S (DOOR SOLENOID) | |
| CSDI0014528 | 00445256 | Starbucks - 58387 | Frisco | TX | UG-44325 | Smart Safe | ZONE1 | NBD | CPI | 1 | 8 | 2026-09-04 04:10 | 2026-09-04 09:14 | 2026-09-04 12:31 | 2026-09-04 12:51 | Dispatched |
On arrival, MOD stated that the got the drawer closed but no...
On arrival, MOD stated that the got the drawer closed but now it wont open all the way. On inspection, found that drawer will only open about two inches before it stops due to an obstruction. After working with it for a few minutes and having to pull vary hard, the drawer eventually opened completely. I looked around all side and then underneath and found the obstruction. A key had fallen down through a narrow slot in the drawer face and was hanging up the bottom of the safe. I was able to remove the key and give it to the manager. The drawer now opens and closes fully and smoothly without issues. Checked solenoid and door sensors to ensure proper operation and that no damage had been done. Everything is now working as intended. No parts needed. Job complete.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014371 | 00442342 | Starbucks - 48576 | Gilbert | AZ | UG-43963 | Smart Safe | ZONE1 | NBD | Burroughs | 7 | 214 | 2026-08-26 13:38 | 2026-08-26 15:59 | 2026-08-26 17:14 | 2026-09-04 11:27 | Dispatched |
Inspected the bottom door 1 and found the rails need replace...
Inspected the bottom door 1 and found the rails need replaced and possibly the drawer front with locking plate. Seated the drawer in the correct closed position and the locking plate will not slide. The locking plate maybe slightly bent. Sent photos to Sesami and on hold 30 minutes. Advised to call back tomorrow for tracking information. ;
Inspected the bottom door 1 and found the rails need replaced and possibly the drawer front with locking plate. Seated the drawer in the correct closed position and the locking plate will not slide. The locking plate maybe slightly bent. Sent photos to Sesami and on hold 30 minutes. Advised to call back tomorrow for tracking information. ;
Part delay;
Part delay;
I put the new side reelings on the door still will not shut. Try to adjust door and take apart. Hinges still couldn't get the door to shut call.Tideel to ask, what should I do?They're ordering a new part;
I put the new side reelings on the door still will not shut. Try to adjust door and take apart. Hinges still couldn't get the door to shut call.Tideel to ask, what should I do?They're ordering a new part;
On site and site os close ;
On site and site os close ;
Arrived onsite and contacted Ashley from Sesami Teir 3. She had me take a large amount of pictures so that they could determine what part(s) were needed to complete this job. I did that and collected the rails left behind so they can be sent back. Interrupting the call per Teir request. Returning used part from previous visit.
4547611 04086464;
Arrived onsite and contacted Ashley from Sesami Teir 3. She had me take a large amount of pictures so that they could determine what part(s) were needed to complete this job. I did that and collected the rails left behind so they can be sent back. Interrupting the call per Teir request. Returning used part from previous visit.
4547611 04086464;
Arrived onsite and called Sesami first thing. I was contacted by our Dispatch earlier in the day that Teir 3 wanted us to check-in before we started. However, there was no other instructions. Spoke to Pete at Sesami and he transferred me to Surge for Teir 3 help, but apparently there were no notes or information left about what they wanted done. Surge checked for any information he could find, but came up short. So, this job has to be interrupted.;
Arrived onsite and called Sesami first thing. I was contacted by our Dispatch earlier in the day that Teir 3 wanted us to check-in before we started. However, there was no other instructions. Spoke to Pete at Sesami and he transferred me to Surge for Teir 3 help, but apparently there were no notes or information left about what they wanted done. Surge checked for any information he could find, but came up short. So, this job has to be interrupted.;
Found the bottom hinge was bent a little and was not allowing the door to close properly. I bent it back in place and sent pics to seasami. Safe is in working order ;
|
Resolved - by field engineer with part replaced (in scope) |
502-1500-400S (SLIDE RACK WIDE DROP VAULT W/ DRAWER (QTY: 1 ...
502-1500-400S (SLIDE RACK WIDE DROP VAULT W/ DRAWER (QTY: 1 PAIR))
|
|
| CSDI0014451 | 00443777 | Starbucks - 10509 | Louisville | KY | UG-38700 | Smart Safe | ZONE1 | NBD | CPI | 1 | 94 | 2026-08-31 11:52 | 2026-08-31 13:06 | 2026-09-04 08:40 | 2026-09-04 09:33 | Dispatched |
Inspection found the bluk note feeders were full of debris a...
Inspection found the bluk note feeders were full of debris and the right side had paper stuck. The bnf had a sticky substance in the bill path. Replace the bulk note feeders. Tested by Mikala mod. Working
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014530 | 00445270 | Starbucks - 7960 | Nashua | NH | UG-41577 | Smart Safe | ZONE1 | NBD | 2 | 2026-09-04 06:49 | 2026-09-04 08:56 | Duplicate | please close duplicate to CSDI0014465/00444040 | Duplicate issue | ||||||
| CSDI0014520 | 00445156 | Starbucks - 6671 | Fullerton | CA | UG-43716 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 5 | 2026-09-03 15:31 | 2026-09-03 16:35 | 2026-09-03 20:35 | 2026-09-03 20:46 | Dispatched |
Picked up part from local fsl, arrived on site. Worked with ...
Picked up part from local fsl, arrived on site. Worked with mod Athena bills were tearing or not accepting. Replaced ba and had Athena test both bas successfully. Safe is up and open.
Return Tracking
1Z7611409052385913;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014462 | 00444010 | Starbucks - 2470 | Mt. Prospect | IL | UG-41175 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 72 | 2026-08-31 19:53 | 2026-09-02 18:49 | 2026-09-03 18:39 | 2026-09-03 19:24 | Dispatched |
Safe was in service on arrival. The manager Brooke told me t...
Safe was in service on arrival. The manager Brooke told me the right BA was jammed. Found a crumbled $20 jammed. Cleared the jam and gave it to the manager Brooke. Cleaned both BA's and found coffee beans in both. Tried to have the manager Brooke test, but was unable to deposit any money at this time. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014464 | 00444039 | Starbucks - 67099 | El Paso | TX | ZA-03009 | Smart Safe | ZONE2 | NBD | CPI | 2 | 64 | 2026-09-01 01:40 | 2026-09-02 14:48 | 2026-09-02 15:37 | 2026-09-03 17:32 | Dispatched |
Spoke with the manager Daphne and she let me know that the s...
Spoke with the manager Daphne and she let me know that the storage door knob had broken off
The nob for the storage door has broken off
I was able to open and close the storage door, even though the knob is broken.
Sesami has sent the parts to replace it
Unfortunately the parts have not arrived
I will incomplete this work order
Spoke with the manager Daphne and she let me know that the storage door knob had broken off
The nob for the storage door has broken off
I was able to open and close the storage door, even though the knob is broken.
Sesami has sent the parts to replace it
Unfortunately the parts have not arrived
I will incomplete this work order
Spoke to the manager tony he had the part to fix the handle
I had to call sesami and get a PACN code
Drilled out the old handel and replaced with the new one
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014465 | 00444040 | Starbucks - 7960 | Nashua | NH | UG-41577 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 60 | 2026-09-01 03:28 | 2026-09-02 13:01 | 2026-09-03 14:43 | 2026-09-03 15:43 | Dispatched |
Upon arrival, the handle is okay and they were confused abo...
Upon arrival, the handle is okay and they were confused about the timing lock and i training her how it work on timing on the drop off vault. ;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014514 | 00445083 | Starbucks - 29856 | Brooklyn | NY | UG-39671 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-03 13:48 | 2026-09-03 14:29 | Phone Fix |
Haley - Starbucks
Problem: No user codes
Clo...
Haley - Starbucks
Problem: No user codes
Closing ticket. User management is to be handle by DEPOSITA
|
Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014496 | 00444652 | Starbucks - 29863 | Mission Hills | CA | UG-43678 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 24 | 2026-09-02 14:02 | 2026-09-02 17:49 | 2026-09-03 13:09 | 2026-09-03 14:19 | Dispatched |
Picked up part from Tamarack Ave warehouse
Arrived onsite w...
Picked up part from Tamarack Ave warehouse
Arrived onsite was given access by Star MOD, I was informed by MOD right side BV was the issue, I proceeded to enter pacn code to gain access to acceptor maintenance door, removed and cleaned both BVs, right side BV not functioning properly, removed RS bv and replaced with new part. Had Star MOD perform a test drop successfully, Safe is up and open
Return Tracking
1Z7611409054656840
1Z7611409054230648;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CS2835145 | 00444925 | Starbucks - 71319 | Wading River | NY | UG-38290 | Smart Safe | ZONE2 | NBD | 3 | 2026-09-03 10:37 | 2026-09-03 13:04 | Phone Fix | Deposita cancelled ticket. | Resolved - by customer | ||||||
| CSDI0014407 | 00443197 | Starbucks - 11281 | Forest Park | OH | UG-38059 | Smart Safe | ZONE1 | NBD | CPI | 2 | 141 | 2026-08-28 15:21 | 2026-08-28 15:16 | 2026-08-29 13:39 | 2026-09-03 12:57 | Dispatched |
Incomplete Biggerstaff 899 need new modem from desposita upo...
Incomplete Biggerstaff 899 need new modem from desposita upon arrival check to see if modem was unplugged. It is not unplugged. Modem left it off for five minutes plugged it back in no change called deposita worked with Angel. We did some more troubleshooting rebooting it again and then holding the reset button for 20 seconds double check connections. After that, he told me that they will be sending a new modem to site case number is CSDI0014407 and for us to call on Monday for tracking
Incomplete Biggerstaff 899 need new modem from desposita upon arrival check to see if modem was unplugged. It is not unplugged. Modem left it off for five minutes plugged it back in no change called deposita worked with Angel. We did some more troubleshooting rebooting it again and then holding the reset button for 20 seconds double check connections. After that, he told me that they will be sending a new modem to site case number is CSDI0014407 and for us to call on Monday for tracking
Arrived on site replaced the modem and it?s peripherals did outgoing XML and FTP. Both were successful encrypted. Call G4S. Worked with Angel he confirmed everything is working. It?s good to go.
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CS2835204 | 00444960 | Starbucks - 78566 | Salinas | CA | UG-44085 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-03 11:10 | 2026-09-03 12:30 | Duplicate | Original case: 00444914 | Duplicate issue | ||||||
| CSDI0014492 | 00444606 | Starbucks - 9359 | Hopkins | MN | UG-38879 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 24 | 2026-09-02 12:25 | 2026-09-02 17:44 | 2026-09-02 19:42 | 2026-09-03 12:18 | Dispatched |
End of shift ;
End of shift ;
On arrival, I spoke with Manag...
End of shift ;
End of shift ;
On arrival, I spoke with Manager Claire, who stated that the right BA was not accepting cash. Upon further inspection, I found heavy coffee spillage on the safe and no power or lights on the right BA. I removed the right BA and found that the cable was unplugged. I reseated the cable, and BA power on. I performed a bill acceptor diagnostic, which showed a failed status. I swapped the left and right BAs and confirmed that the issue followed the BA. I replaced the right BA and ran another diagnostic, which showed all statuses as normal. I then had Claire perform a deposit test, during which she experienced difficulty depositing into the left BA. I removed the left BA and found coffee beans inside the unit. I cleaned and wiped down the BA, reinstalled it, and had Claire perform another deposit test. She was able to successfully deposit cash into both BAs. Safe is up and operational. Advised the site to prevent future spills on or around the safe to avoid equipment damage.;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014510 | 00444897 | Starbucks - 66057 | Maple Grove | MN | UG-39572 | Smart Safe | ZONE1 | NBD | 0 | 2026-09-03 09:31 | 2026-09-03 09:42 | Phone Fix | User Management is handle by Deposita. | Resolved - by field engineer with NO part replaced (in scope) | ||||||
| CSDI0014475 | 00444241 | Starbucks - 67572 | Byram | MS | ZA-02929 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 44 | 2026-09-01 13:37 | 2026-09-01 15:07 | 2026-09-03 09:04 | 2026-09-03 09:12 | Dispatched |
Upon arrival the manager had already removed the damaged bv ...
Upon arrival the manager had already removed the damaged bv and I replaced it. I had the manager to test bills on each side. All bills deposit with no issues. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014505 | 00444823 | Starbucks - 9843 | Reno | NV | UG-43831 | Smart Safe | ZONE3 | NBD | 0 | 8 | 2026-09-03 00:04 | 2026-09-03 00:04 | 2026-09-03 08:57 | Dispatched | g4s called to cancel the service call. posted in fsl as well | Resolved - by 3rd party second line support | ||||
| CSDI0014490 | 00444599 | Starbucks - 3389 | Tigard | OR | UG-38041 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 9 | 2026-09-02 12:08 | 2026-09-02 17:58 | 2026-09-02 20:58 | 2026-09-02 21:26 | Dispatched |
Picked up part from FSL > arrived onsite > replaced pr...
Picked up part from FSL > arrived onsite > replaced printer > tested - normal operation > prepared part for return shipping (attached);
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402S (PRINTER KFI INTEGRATED (BUILT-IN) SERIES 4) | |
| CSDI0014478 | 00444295 | Starbucks - 54504 | North Kansas City | MO | ZA-04264 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 28 | 2026-09-01 15:05 | 2026-09-01 19:31 | 2026-09-02 18:45 | 2026-09-02 19:05 | Dispatched |
Arrived to site examined unit found torn 20 in left ba remov...
Arrived to site examined unit found torn 20 in left ba removed bill and tested unit with mod. No further issues found closing call. ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014476 | 00444243 | Starbucks - 65965 | Reno | NV | UG-38414 | Smart Safe | ZONE3 | NBD | Burroughs | 1 | 27 | 2026-09-01 13:38 | 2026-09-01 19:16 | 2026-09-02 15:54 | 2026-09-02 16:58 | Dispatched |
Left BV jammed on arrival, opened and found part of a torn $...
Left BV jammed on arrival, opened and found part of a torn $1, cleared jam and tested ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014436 | 00443551 | Starbucks - 51248 | Ankeny | IA | UG-39743 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 74 | 2026-08-30 15:42 | 2026-08-30 18:04 | 2026-09-02 16:23 | 2026-09-02 17:22 | Dispatched |
Arrived, spoke to manager, found unit offline, opened the ma...
Arrived, spoke to manager, found unit offline, opened the main panel, found it offline, per technician Ben: found the breaker box, found the safe breaker not flipped, left it alone, used my meter to test if power was coming at all, the manager mentioned one of the registers on the counter was also not getting any power and that made me think of the six plug under the counter, before I started opening the counter however I went back to the breaker box found the safe and pressed the "test" button then flipped the breaker back on, came back turned on the safe, safe turned on, it gave me the message that it was offline for to long, called tidel got Trinidad, got a pacn, called deposita, got justin, checked connection, safe was connected and running, prepped parts for return, got signature, closed safe panel;
|
Resolved - by field engineer with part replaced (in scope) |
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 6...
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB), 642-0002-101S (POWER SUPPLY SERIES 4 RIGHT SIDE & S5), 642-0015-101S (POWER SUPPLY SERIES 4 LEFT SIDE)
|
|
| CSDI0014457 | 00443925 | Starbucks - 3386 | Clackamas | OR | UG-38012 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 49 | 2026-08-31 15:48 | 2026-08-31 19:02 | 2026-09-01 18:12 | 2026-09-02 16:52 | Dispatched |
Arrived onsite, worked with MoD Jake.
On arrival NO BVs are...
Arrived onsite, worked with MoD Jake.
On arrival NO BVs are inside unit, both out and inoperable according to site.
Inserted old BVs, both are spiraling in a loop. Inserted single received BV in both slots to test functionality, new BV seems to be fine in both slots.
Attempted to field repair/troubleshoot old BVs but tongue is stuck up on one and the other wont get out of loop. Reseated MEI cards and Cassettes to find a change, it appears both site BVs are bad and we need one more.
Spoke with Jarran at sesami, one more BV is being sent to site. Informed site MoD Jake of situation. ;
Arrived onsite, worked with MoD Jake.
On arrival NO BVs are inside unit, both out and inoperable according to site.
Inserted old BVs, both are spiraling in a loop. Inserted single received BV in both slots to test functionality, new BV seems to be fine in both slots.
Attempted to field repair/troubleshoot old BVs but tongue is stuck up on one and the other wont get out of loop. Reseated MEI cards and Cassettes to find a change, it appears both site BVs are bad and we need one more.
Spoke with Jarran at sesami, one more BV is being sent to site. Informed site MoD Jake of situation. ;
Arrived on site, installed new acceptor. Not reading, reseating MEI cards. Successful, acceptor now reading. Performing test deposit, successful. Issue resopved;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014375 | 00442458 | Starbucks - 61257 | Springfield | IL | UG-39680 | Smart Safe | ZONE4 | NBD | Burroughs | 3 | 167 | 2026-08-26 17:50 | 2026-08-26 18:26 | 2026-08-28 12:52 | 2026-09-02 16:52 | Dispatched |
I arrived on-site to replace the part.It had already been re...
I arrived on-site to replace the part.It had already been replaced, but the error was still persistent.I gained access to the cassettes.No jams were present.They were all seated properly.Still running into that error I swapped the cassettes position.The error followed over to spot.One eye contacted tiedle , and they are ordering a new cassette;
I arrived on-site to replace the part.It had already been replaced, but the error was still persistent.I gained access to the cassettes.No jams were present.They were all seated properly.Still running into that error I swapped the cassettes position.The error followed over to spot.One eye contacted tiedle , and they are ordering a new cassette;
No tracking or order information from Tidel in call for replacement casette. Replacement casette not on site and has not been ordered by Tidel. Contacted tidel and they said they would update ticket when part was shipped. Removed unused Bill acceptor from site and processed for return. Interrupting task for customer supplied part needed. ;
No tracking or order information from Tidel in call for replacement casette. Replacement casette not on site and has not been ordered by Tidel. Contacted tidel and they said they would update ticket when part was shipped. Removed unused Bill acceptor from site and processed for return. Interrupting task for customer supplied part needed. ;
Verified casette not needed and cleared printer jam causing unable to print condition. Tested and verified with site staff closing task safe is fully functional. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0106-200S (CASSETTE (MEI SCL) ALL COUNTRIES)
|
|
| CSDI0014482 | 00444346 | Starbucks - 19869 | Nampa | ID | UG-38512 | Smart Safe | ZONE4 | NBD | Burroughs | 1 | 23 | 2026-09-01 16:27 | 2026-09-01 18:35 | 2026-09-02 15:08 | 2026-09-02 15:30 | Dispatched | Cleared jam from BA1. Tested with MOD. Operable ; | Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014440 | 00443578 | Starbucks - 28060 | Billings | MT | UG-44251 | Smart Safe | ZONE4 | NBD | Burroughs | 2 | 68 | 2026-08-30 19:57 | 2026-08-31 12:55 | 2026-09-02 09:43 | 2026-09-02 15:12 | Dispatched |
Spoke to manager - will return between 1 and 2;
Spoke to man...
Spoke to manager - will return between 1 and 2;
Spoke to manager - will return between 1 and 2;
Arrived onsite,
PACN - 0732155284
Entered PACN - acceptor maintenance door is not opening. Opened courier door to gain access to BA. Found that right BA head was not attached to BA. Attached head to BA. Successfully tested unit.
Return tracking 4547611 04089113;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014394 | 00443945 | Starbucks - 78566 | Salinas | CA | UG-44085 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 47 | 2026-08-31 16:23 | 2026-08-31 20:11 | 2026-09-02 12:47 | 2026-09-02 15:10 | Dispatched |
Arrived on site. Google maps shows the ads different. Called...
Arrived on site. Google maps shows the ads different. Called POC and talked with Matt. He explained where it was. Called poc and he said there was an access for back of safe in front of customer counter. Remvoed access panel and found broken wires for the power cord. Followed it into the safe and it looked like it went behind chasis. Removed chassis and the modem was going into door2. Opened door 2 and had to empty all contents of rolled coins. Plugged in the new router and the safe is back online and put all rolled coins back in. Checked and safe is online. Called Deposita and waited for Angel to test connection. Angel put me on hold to see if I needed to replace modem. Angel said to replace it. Removed all rolled coins again and replaced modem. Called Deposita back and talked to Angel. He said it was online. I told him there wasn't a return label. He sent an email requesting return label.;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014483 | 00444347 | Starbucks - 9362 | Charlotte | NC | UG-38103 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 18 | 2026-09-01 16:28 | 2026-09-01 19:20 | 2026-09-02 09:42 | 2026-09-02 10:44 | Dispatched |
Arrived on-site and met with the MOD who who told me the iss...
Arrived on-site and met with the MOD who who told me the issue. The safe was off as it was beeping constantly when I turned it on. I replaced the BA and tested both sides. And both work. Also tested the printer as it was right underneath and was working properly, no liquid was found. Spoke to Jeremy from tidel and told him the issue (also sent me a return label) and suggested that it would be moved to a different location. He told me that would be for the store to do. I went back in and spoke to the District manager and made the same suggestion as it could cost more money and/or void warranty if there is one. The safe is right under the counter, right next to the register and an ice machine...not safe at all. ;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014481 | 00444331 | Starbucks - 65241 | Mesa | AZ | UG-44347 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 18 | 2026-09-01 16:03 | 2026-09-01 18:38 | 2026-09-02 10:14 | 2026-09-02 10:40 | Dispatched |
Inspected door 1 and adjusted door 1 and it's working really...
Inspected door 1 and adjusted door 1 and it's working really good. Safe is in working order ;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014485 | 00444407 | Starbucks - 10476 | Richland | WA | ZA-04443 | Smart Safe | ZONE4 | NBD | Burroughs | 1 | 15 | 2026-09-01 19:35 | 2026-09-01 21:16 | 2026-09-02 10:03 | 2026-09-02 10:24 | Dispatched |
Arrived on site and verified safe. BA2 has Jam status. Remov...
Arrived on site and verified safe. BA2 has Jam status. Removed ba2 and noticed a $10 inside BA. Removed note and handed to Fee manning (manager). Performed PM on BA2. Noticed coin inside BA1 so I removed it and performed PM on that BA as well. Both BA's have status of READY. Voltage good as well. Had Fee manning test both BA's and are working. Smart safe is back in service;
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014488 | 00444434 | Starbucks - 9362 | Charlotte | NC | UG-38103 | Smart Safe | ZONE1 | NBD | 1 | 2026-09-02 06:41 | 2026-09-02 07:20 | Phone Fix |
Please combine the 2 cases  salesforce case#00444434 & 0044...
Please combine the 2 cases  salesforce case#00444434 & 00444347. These 2 cases are for the same location. 1st ticket 00444347  2nd ticket 00444434 . The new ticket with beeping noise coming from the ba. Due to the issues on the 1st ticket.
|
Resolved - by 3rd party second line support | ||||||
| CSDI0014453 | 00443848 | Starbucks - 51180 | Los Angeles | CA | UG-44130 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 31 | 2026-08-31 13:15 | 2026-08-31 17:29 | 2026-09-01 19:51 | 2026-09-01 20:17 | Dispatched |
Picked up part from Tamarack Ave warehouse
Arrived onsite w...
Picked up part from Tamarack Ave warehouse
Arrived onsite was given access by Cesar MOD, was informed by MOD left bill acceptor was not functioning properly, presided to enter pacn code to gain access to acceptor maintenance door, remove left BB replace with new parts, navigate it to voltage, found voltage to be at the accurate threshold, both bvs showing ready in device menu. Had Cesar mod perform a drop test successfully. Safe is and open.
Return Tracking
1Z7611409053230793;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014471 | 00444164 | Starbucks - 8291 | Atlanta | GA | UG-38065 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 10 | 2026-09-01 11:17 | 2026-09-01 17:02 | 2026-09-01 21:20 | 2026-09-01 21:22 | Dispatched |
Per Deposita, Quote was not approved and was advised to clos...
Per Deposita, Quote was not approved and was advised to closed ticket
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014456 | 00443921 | Starbucks - 5997 | San Diego | CA | ZA-04616 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 27 | 2026-08-31 15:39 | 2026-08-31 19:09 | 2026-09-01 18:02 | 2026-09-01 18:49 | Dispatched |
Arrived on-site to inspect safe's printer. Upon testing prin...
Arrived on-site to inspect safe's printer. Upon testing printer was getting jammed. Tried cleaning the printer and its gears but was unable to fix the issue. I removed and replaced the printer. After replacing part I had Ms. Keelee test it successfully. Preformed multiple printer test successfully.;
|
Resolved - by field engineer with part replaced (in scope) | 644-0132-402S (PRINTER KFI INTEGRATED (BUILT-IN) SERIES 4) | |
| CSDI0014274 | 00443967 | Starbucks - 6721 | Dallas | TX | ZA-03136 | Smart Safe | ZONE1 | NBD | CPI | 1 | 25 | 2026-08-31 16:58 | 2026-08-31 20:10 | 2026-09-01 17:14 | 2026-09-01 17:42 | Dispatched |
Onsite spoke to mod about safe offline installed new modem s...
Onsite spoke to mod about safe offline installed new modem sent to site and contacted donald at g4 to check connection on his side and everything was good.was told to close call.av925
|
Resolved - by field engineer with NO part replaced (in scope) | ||
| CSDI0014460 | 00443938 | Starbucks - 695 | Dallas | TX | ZA-03107 | Smart Safe | ZONE1 | NBD | CPI | 1 | 24 | 2026-08-31 16:09 | 2026-08-31 21:08 | 2026-09-01 14:22 | 2026-09-01 16:34 | Dispatched |
onsite spoke w MOD re Modem not communicating and door 1 han...
onsite spoke w MOD re Modem not communicating and door 1 handle broke off and needs replacement drilled out remains of handle and replaced 502136300 successfully also was able to get modem an safe online with power cycle then logged into unit ran baseline checks device status diagnostics voltage test all ok verified vault doors closed secure no safety issues checked connections and overall condition confirmed system integrity had customer test doors successfully issues resolved to customer satisfaction closing call av925
|
Resolved - by field engineer with part replaced (in scope) |
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-402R (PR...
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-402R (PRINTER KFI), 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR)
|
|
| CSDI0014435 | 00443536 | Starbucks - 9666 | Portland | OR | ZA-04544 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 50 | 2026-08-30 14:37 | 2026-08-30 15:45 | 2026-09-01 15:08 | 2026-09-01 16:32 | Dispatched |
Arrived onsite, able to open drop vault (labeled door 1) wit...
Arrived onsite, able to open drop vault (labeled door 1) with needle pliers. Previously installed knob broken off, epoxy used jammed in knob hole. Removing cash from drop vault, disassembling drop vault assembly to remove lock plate. Locking plate removed, drilling epoxy out. Epoxy removed, threads in plate still usable, installing knew knob. New knob installed, drop vault able to be opened and closed using new knob installed. Issue resolved, closing out ticket.;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014468 | 00444081 | Starbucks - 2763 | Frankfort | KY | UG-38704 | Smart Safe | ZONE2 | NBD | CPI | 1 | 4 | 2026-09-01 08:30 | 2026-09-01 11:47 | 2026-09-01 12:54 | Dispatched | Resolved - by 3rd party second line support | ||||
| CSDI0014461 | 00444007 | Starbucks - 50181 | Big Spring | TX | ZA-02997 | Smart Safe | ZONE1 | NBD | 0 | 17 | 2026-08-31 19:32 | 2026-08-31 19:32 | 2026-09-01 12:03 | Dispatched |
Per Deposita, Approval for the referenced Work Task was not ...
Per Deposita, Approval for the referenced Work Task was not received within the allotted timeframe and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014411 | 00443264 | Starbucks - 15748 | Woodhaven | MI | UG-39604 | Smart Safe | ZONE1 | NBD | Burroughs | 2 | 87 | 2026-08-28 19:29 | 2026-08-29 05:17 | 2026-08-30 08:12 | 2026-09-01 10:19 | Dispatched |
Arrived on site and inspected safe found bad bill acceptor c...
Arrived on site and inspected safe found bad bill acceptor called Sesami they said part was at FSL waiting for pickup, I arrived at FSL and it was closed ;
Arrived on site and inspected safe found bad bill acceptor called Sesami they said part was at FSL waiting for pickup, I arrived at FSL and it was closed ;
Bill acceptor failure
Replaced LHS acceptor and tested with the manager;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
|
| CSDI0014390 | 00442706 | Starbucks - 8541 | Bradenton | FL | UG-38166 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 98 | 2026-08-27 12:50 | 2026-08-28 10:32 | 2026-08-31 13:24 | 2026-08-31 14:08 | Dispatched |
Arrived on site replaced right acceptor and acceptor mainten...
Arrived on site replaced right acceptor and acceptor maintenance door solenoid. Test passed. Asked site to test bv succesful. Issue resolved return tracking 9612018454761104087102;
|
Resolved - by field engineer with part replaced (in scope) |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 201-2714-012S (SOLENOID SLOTTED PLUNGER 12")
|
|
| CSDI0014449 | 00443760 | Starbucks - 21218 | Raleigh | NC | UG-38553 | Smart Safe | ZONE1 | NBD | 1 | 2026-08-31 11:25 | 2026-08-31 12:36 | Phone Fix |
Customer press the power on the safe on the side which then ...
Customer press the power on the safe on the side which then powered up the unit. we then put in a note which took. closing ticket
|
Resolved - by 3rd party second line support | ||||||
| CSDI0014441 | 00443617 | Starbucks 13383 | Glen Ridge | NJ | UG-43510 | Smart Safe | ZONE1 | NBD | 0 | 8 | 2026-08-31 04:40 | 2026-08-31 04:40 | 2026-08-31 12:31 | Dispatched |
Per Deposita, they did not receive any response and was advi...
Per Deposita, they did not receive any response and was advised to close ticket.
|
Resolved - by field engineer with NO part replaced (in scope) | ||||
| CSDI0014434 | 00443555 | Starbucks - 7348 | Hoboken | NJ | UG-38467 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 20 | 2026-08-30 16:05 | 2026-08-30 17:51 | 2026-08-31 11:40 | 2026-08-31 12:27 | Dispatched |
Door handle not broken
Door handle not broken
No replacement...
Door handle not broken
Door handle not broken
No replacement of door handle, cancel call/ticket.;
|
Resolved - by field engineer with part replaced (in scope) | 502-1363-001S (HANDLE BALL BILL VAL DOOR) | |
| CSDI0014423 | 00443428 | Starbucks - 11431 | Little Rock | AR | UG-41209 | Smart Safe | ZONE1 | NBD | Burroughs | 1 | 39 | 2026-08-29 21:11 | 2026-08-30 15:09 | 2026-08-31 11:30 | 2026-08-31 12:15 | Dispatched |
Arrived onsite duplicated issue with store manager Jamie I t...
Arrived onsite duplicated issue with store manager Jamie I took apart and blew out both bill acceptors switched both mei boards as well as bill acceptors after noticing the left one didn't take any bills and the right one was making loud popping noises due to a paper clip that was jammed deep inside the mouth of the right bill acceptor and the left one had an old bill ripped up inside it and a coffee bean after all jams were found and cleared we ran a couple note tests and both bill acceptors are now back online and operating as normal ;
|
Resolved - by field engineer with NO part replaced (in scope) |