Total OOS
49
Unique Serials
48
Out of Scope
49 rows
| CS Number | SF Case | Service Call | Invoice Date | Amount | Store | City | State | Serial | Unit Type | Equipment | OOS Reason | Entry Date/Time | Dispatched | First Onsite | Completed | Closed | Parts | Comment |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CSDI0014274 | 00443967 | 1548825 | 2026-09-08 | 468.00 | Starbucks 6721 | Dallas | TX | ZA-03136 | Smart Safe | SmartSafe | OTHER | 2026-08-31 16:58:00 | 2026-08-31 20:10:00 | 2026-09-01 17:14:00 | 2026-09-01 17:42:00 | 2026-09-01 17:44 |
2026-09-01 Completed: Onsite spoke to mod about safe offline...
2026-09-01 Completed: Onsite spoke to mod about safe offline installed new modem sent to site and contacted donald at g4 to check connection on his side and everything was good.was told to close call.av925 Non-Device Related Issue - Communications (Telephone, network, or utility failures, modems, routers, switches)
|
|
| CSDI0014371 | 00442342 | 1547305 | 2026-09-08 | 1069.87 | Starbucks 48576 | Gilbert | AZ | UG-43963 | Smart Safe | SmartSafe | CUSTOMER_DAMAGE | 2026-08-26 13:38:00 | 2026-08-26 15:59:00 | 2026-08-26 17:14:00 | 2026-09-04 11:27:00 | 2026-09-04 11:30 |
502-1500-400S (SLIDE RACK WIDE DROP VAULT W/ DRAWER (QTY: 1 ...
502-1500-400S (SLIDE RACK WIDE DROP VAULT W/ DRAWER (QTY: 1 PAIR))
|
09/04/2026 Completed: Found the bottom hinge was bent a litt...
09/04/2026 Completed: Found the bottom hinge was bent a little and was not allowing the door to close properly. I bent it back in place and sent pics to seasami. Safe is in working order Operational Issues - Improper Handling (Vault doors not secure, additional training needed, minor repairable damage, alignment, etc.)
|
| CSDI0014556 | 00445686 | 1550516 | 2026-09-08 | 2499.28 | Starbucks 701 | Alexandria | VA | ZA-03162 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-09-05 13:16:00 | 2026-09-05 15:09:00 | 2026-09-06 08:35:00 | 2026-09-06 09:27:00 | 2026-09-06 09:28 |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
2026-09-06 Completed: onsite spoke w MOD re Right acceptor h...
2026-09-06 Completed: onsite spoke w MOD re Right acceptor had creamer spilled inside and not working issue confirmed via system behavior replaced 845.z206.r0 then logged into unit ran baseline checks device status diagnostics voltage test all ok verified vault doors closed secure no safety issues checked connections and overall condition confirmed system integrity had customer test acceptors successfully issues resolved to customer satisfaction closing call av925 Abuse - Spillage
|
| CSDI0014528 | 00445256 | 1550145 | 2026-09-08 | 468.00 | Starbucks 58387 | Frisco | TX | UG-44325 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-09-04 04:10:00 | 2026-09-04 09:14:00 | 2026-09-04 12:31:00 | 2026-09-04 12:51:00 | 2026-09-04 12:52 |
2026-09-04 Completed: On arrival, MOD stated that the got th...
2026-09-04 Completed: On arrival, MOD stated that the got the drawer closed but now it wont open all the way. On inspection, found that drawer will only open about two inches before it stops due to an obstruction. After working with it for a few minutes and having to pull vary hard, the drawer eventually opened completely. I looked around all side and then underneath and found the obstruction. A key had fallen down through a narrow slot in the drawer face and was hanging up the bottom of the safe. I was able to remove the key and give it to the manager. The drawer now opens and closes fully and smoothly without issues. Checked solenoid and door sensors to ensure proper operation and that no damage had been done. Everything is now working as intended. No parts needed. Job complete. Abuse - Foreign Object – No Part Replaced
|
|
| CSDI0014375 | 00442458 | 1547387 | 2026-09-08 | 835.50 | Starbucks 61257 | Springfield | IL | UG-39680 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-26 17:50:00 | 2026-08-26 18:26:00 | 2026-08-28 12:52:00 | 2026-09-02 16:52:00 | 2026-09-02 15:58 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0106-200S (CASSETTE (MEI SCL) ALL COUNTRIES)
|
09/02/2026 Completed: Verified casette not needed and cleare...
09/02/2026 Completed: Verified casette not needed and cleared printer jam causing unable to print condition. Tested and verified with site staff closing task safe is fully functional. Jams – No Part Used/Cleaning Only - Printer
|
| CSDI0014538 | 00445456 | 1550299 | 2026-09-08 | 585.00 | Starbucks 22307 | Houston | TX | ZA-04298 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-04 13:46:00 | 2026-09-04 16:05:00 | 2026-09-05 08:54:00 | 2026-09-05 10:23:00 | 2026-09-05 10:24 | 632-0012-110S (SENSOR KIT VAULT DOORS (2 PER) WIDE) |
2026-09-05 Completed: ***TECH#196 CATO***
On site 9/5@8:55am...
2026-09-05 Completed: ***TECH#196 CATO***
On site 9/5@8:55am. On arrival Door 2 was working and the sensors were functioning as they should, however the lock bar was binding up when trying to close. I disassembled the door and found dried grease on the bushings inside. Cleaned off dried grease from bushings and relubricated. Also, the set screws that stabalize the lock bar had backed out of place, applied Loctite to screws and adjusted. Reassembled door and tested repeatedly. No parts replaced, see photos attached Jams – No Part Used/Cleaning Only - Vault Doors
|
| CSDI0014531 | 00445272 | 1550254 | 2026-09-08 | 543.00 | Starbucks 22003 | Portland | OR | ZA-02976 | Smart Safe | SmartSafe | NO_PROBLEM_FOUND | 2026-09-04 06:58:00 | 2026-09-04 14:06:00 | 2026-09-05 18:56:00 | 2026-09-05 19:24:00 | 2026-09-04 19:00 |
205-4086-001S (SOLENOID ASSY W/ ANTI-THEFT), 210-0510-107R (...
205-4086-001S (SOLENOID ASSY W/ ANTI-THEFT), 210-0510-107R (PCB CONTROL PANEL RECONDITIONED (G4S)), 642-0002-101S (POWER SUPPLY SERIES 4 RIGHT SIDE & S5)
|
09/05/2026 Completed: Arrived on site, manager disclosed iss...
09/05/2026 Completed: Arrived on site, manager disclosed issue had been resolved prior to arrival. Tested unit drop vault solenoid just to verify, confirmed. Safe in working condition. Informed from manager that ticket was meant to be closed prior to arrival. Confirmed status/condition of safe, issue resolved. Closing out ticket Non-Device Related Issue - No problem found/Call Cancellation request received too late
|
| CSDI0014465 | 00444040 | 1548928 | 2026-09-08 | 718.50 | Starbucks 7960 | Nashua | NH | UG-41577 | Smart Safe | SmartSafe | ALIGNMENT | 2026-09-01 03:28:00 | 2026-09-02 13:01:00 | 2026-09-03 14:43:00 | 2026-09-03 15:43:00 | 2026-09-03 15:47 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
09/03/2026 Completed: Upon arrival, the handle is okay and ...
09/03/2026 Completed: Upon arrival, the handle is okay and they were confused about the timing lock and i training her how it work on timing on the drop off vault. Operational Issues - Improper Handling (Vault doors not secure, additional training needed, minor repairable damage, alignment, etc.)
|
| CSDI0014435 | 00443536 | 1548499 | 2026-09-08 | 760.29 | Starbucks 9666 | Portland | OR | ZA-04544 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-08-30 14:37:00 | 2026-08-30 15:45:00 | 2026-09-01 15:08:00 | 2026-09-01 16:32:00 | 2026-09-01 16:35 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
09/01/2026 Completed: Arrived onsite, able to open drop vaul...
09/01/2026 Completed: Arrived onsite, able to open drop vault (labeled door 1) with needle pliers. Previously installed knob broken off, epoxy used jammed in knob hole. Removing cash from drop vault, disassembling drop vault assembly to remove lock plate. Locking plate removed, drilling epoxy out. Epoxy removed, threads in plate still usable, installing knew knob. New knob installed, drop vault able to be opened and closed using new knob installed. Issue resolved, closing out ticket. Abuse - Physical Damage
|
| CSDI0014476 | 00444243 | 1549113 | 2026-09-08 | 526.50 | Starbucks 65965 | Reno | NV | UG-38414 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-01 13:38:00 | 2026-09-01 19:16:00 | 2026-09-02 15:54:00 | 2026-09-02 16:58:00 | 2026-09-02 17:30 |
09/02/2026 Completed: Left BV jammed on arrival, opened and ...
09/02/2026 Completed: Left BV jammed on arrival, opened and found part of a torn $1, cleared jam and tested Jams – No Part Used/Cleaning Only - Bill Acceptors/Validator
|
|
| CSDI0014460 | 00443938 | 1548822 | 2026-09-08 | 584.79 | Starbucks - 695 | Dallas | TX | ZA-03107 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-08-31 16:09:00 | 2026-08-31 21:08:00 | 2026-09-01 14:22:00 | 2026-09-01 16:34:00 | 2026-09-01 16:36 |
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-402R (PR...
502-1363-001S (HANDLE BALL BILL VAL DOOR), 644-0132-402R (PRINTER KFI), 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR)
|
2026-09-01 Completed: onsite spoke w MOD re Modem not commun...
2026-09-01 Completed: onsite spoke w MOD re Modem not communicating and door 1 handle broke off and needs replacement drilled out remains of handle and replaced 502136300 successfully also was able to get modem an safe online with power cycle then logged into unit ran baseline checks device status diagnostics voltage test all ok verified vault doors closed secure no safety issues checked connections and overall condition confirmed system integrity had customer test doors successfully issues resolved to customer satisfaction closing call av925 Abuse - Physical Damage
|
| CSDI0014407 | 00443197 | 1548062 | 2026-09-08 | 468.00 | Starbucks 11281 | Forest Park | OH | UG-38059 | Smart Safe | SmartSafe | OTHER | 2026-08-28 15:21:00 | 2026-08-28 15:16:00 | 2026-08-29 13:39:00 | 2026-09-03 12:57:00 | 2026-09-03 12:57 |
2026-09-03 Completed: Arrived on site replaced the modem and...
2026-09-03 Completed: Arrived on site replaced the modem and it?s peripherals did outgoing XML and FTP. Both were successful encrypted. Call G4S. Worked with Angel he confirmed everything is working. It?s good to go. Non-Device Related Issue - Communications (Telephone, network, or utility failures, modems, routers, switches)
|
|
| CSDI0014504 | 00444820 | 1549706 | 2026-09-08 | 1052.79 | Starbucks 21800 | Los Angeles | CA | UG-43624 | Smart Safe | SmartSafe | CUSTOMER_DAMAGE | 2026-09-02 22:53:00 | 2026-09-03 08:09:00 | 2026-09-04 13:49:00 | 2026-09-05 13:58:00 | 2026-09-05 14:02 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
09/05/2026 Completed: I requested cover doir to be replaced ...
09/05/2026 Completed: I requested cover doir to be replaced as it had broken washers. I was instructed to locally source them. It took me 3 trips to Lowes. Successfully bumped out door so it didnt hit locking rails. Successfully tested door with MOD helen.. Operational Issues - Improper Handling (Vault doors not secure, additional training needed, minor repairable damage, alignment, etc.)
|
| CSDI0014492 | 00444606 | 1549581 | 2026-09-08 | 1863.33 | Starbucks 9359 | Hopkins | MN | UG-38879 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-09-02 12:25:00 | 2026-09-02 17:44:00 | 2026-09-02 19:42:00 | 2026-09-03 12:18:00 | 2026-09-03 12:26 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
09/03/2026 Completed: On arrival, I spoke with Manager Clair...
09/03/2026 Completed: On arrival, I spoke with Manager Claire, who stated that the right BA was not accepting cash. Upon further inspection, I found heavy coffee spillage on the safe and no power or lights on the right BA. I removed the right BA and found that the cable was unplugged. I reseated the cable, and BA power on. I performed a bill acceptor diagnostic, which showed a failed status. I swapped the left and right BAs and confirmed that the issue followed the BA. I replaced the right BA and ran another diagnostic, which showed all statuses as normal. I then had Claire perform a deposit test, during which she experienced difficulty depositing into the left BA. I removed the left BA and found coffee beans inside the unit. I cleaned and wiped down the BA, reinstalled it, and had Claire perform another deposit test. She was able to successfully deposit cash into both BAs. Safe is up and operational. Advised the site to prevent future spills on or around the safe to avoid equipment damage. Abuse - Spillage
|
| CSDI0014485 | 00444407 | 1549208 | 2026-09-08 | 468.00 | Starbucks 10476 | Richland | WA | ZA-04443 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-09-01 19:35:00 | 2026-09-01 21:16:00 | 2026-09-02 10:03:00 | 2026-09-02 10:24:00 | 2026-09-02 10:27 |
09/02/2026 Completed: Arrived on site and verified safe. BA2...
09/02/2026 Completed: Arrived on site and verified safe. BA2 has Jam status. Removed ba2 and noticed a $10 inside BA. Removed note and handed to Fee manning (manager). Performed PM on BA2. Noticed coin inside BA1 so I removed it and performed PM on that BA as well. Both BA's have status of READY. Voltage good as well. Had Fee manning test both BA's and are working. Smart safe is back in service Abuse - Foreign Object – No Part Replaced
|
|
| CSDI0014478 | 00444295 | 1549121 | 2026-09-08 | 468.00 | Starbucks 54504 | North Kansas City | MO | ZA-04264 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-01 15:05:00 | 2026-09-01 19:31:00 | 2026-09-02 18:45:00 | 2026-09-02 19:05:00 | 2026-09-02 19:09 |
09/02/2026 Completed: Arrived to site examined unit found to...
09/02/2026 Completed: Arrived to site examined unit found torn 20 in left ba removed bill and tested unit with mod. No further issues found closing call. Jams – No Part Used/Cleaning Only - Bill Acceptors/Validator
|
|
| CSDI0014462 | 00444010 | 1548844 | 2026-09-08 | 526.50 | Starbucks 2470 | Mt. Prospect | IL | UG-41175 | Smart Safe | SmartSafe | NO_ISSUE_ON_ARRIVAL | 2026-08-31 19:53:00 | 2026-09-02 18:49:00 | 2026-09-03 18:39:00 | 2026-09-03 19:24:00 | 2026-09-03 19:28 |
09/03/2026 Completed: Safe was in service on arrival. The ma...
09/03/2026 Completed: Safe was in service on arrival. The manager Brooke told me the right BA was jammed. Found a crumbled $20 jammed. Cleared the jam and gave it to the manager Brooke. Cleaned both BA's and found coffee beans in both. Tried to have the manager Brooke test, but was unable to deposit any money at this time. Abuse - Foreign Object – No Part Replaced
|
|
| CSDI0014440 | 00443578 | 1548531 | 2026-09-08 | 543.00 | Starbucks - 28060 | Billings | MT | UG-44251 | Smart Safe | SmartSafe | COURIER_DAMAGE | 2026-08-30 19:57:00 | 2026-08-31 12:55:00 | 2026-09-02 09:43:00 | 2026-09-02 15:12:00 | 2026-09-02 15:17 |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
09/02/2026 Completed: Arrived onsite,
PACN - 0732155284
Ente...
09/02/2026 Completed: Arrived onsite,
PACN - 0732155284
Entered PACN - acceptor maintenance door is not opening. Opened courier door to gain access to BA. Found that right BA head was not attached to BA. Attached head to BA. Successfully tested unit.
Return tracking 4547611 04089113 Operational Issues - Improper Handling (Vault doors not secure, additional training needed, minor repairable damage, alignment, etc.)
|
| CSDI0014436 | 00443551 | 1548510 | 2026-09-08 | 543.00 | Starbucks 51248 | Ankeny | IA | UG-39743 | Smart Safe | SmartSafe | CUSTOMER_CAUSED | 2026-08-30 15:42:00 | 2026-08-30 18:04:00 | 2026-09-02 16:23:00 | 2026-09-02 17:22:00 | 2026-09-02 17:26 |
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 6...
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 633-0020-007S (Do not Use DISPLAY/TOUCHSCREEN ASSEMBLY WITH BACKLIGHT BULB), 642-0002-101S (POWER SUPPLY SERIES 4 RIGHT SIDE & S5), 642-0015-101S (POWER SUPPLY SERIES 4 LEFT SIDE)
|
09/02/2026 Completed: Arrived, spoke to manager, found unit ...
09/02/2026 Completed: Arrived, spoke to manager, found unit offline, opened the main panel, found it offline, per technician Ben: found the breaker box, found the safe breaker not flipped, left it alone, used my meter to test if power was coming at all, the manager mentioned one of the registers on the counter was also not getting any power and that made me think of the six plug under the counter, before I started opening the counter however I went back to the breaker box found the safe and pressed the "test" button then flipped the breaker back on, came back turned on the safe, safe turned on, it gave me the message that it was offline for to long, called tidel got Trinidad, got a pacn, called deposita, got justin, checked connection, safe was connected and running, prepped parts for return, got signature, closed safe panel Non-Device Related Issue - Site power issues/power outages/Unit not plugged in or according to manufacturer specifications
|
| CSDI0014526 | 00445249 | 1550056 | 2026-09-08 | 643.50 | Starbucks 6551 | Fremont | CA | UG-43766 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-03 22:21:00 | 2026-09-04 11:50:00 | 2026-09-04 20:03:00 | 2026-09-04 20:25:00 | 2026-09-04 20:28 |
09/04/2026 Completed: Cleared jammed $20 from left note acce...
09/04/2026 Completed: Cleared jammed $20 from left note acceptor. Had mod Elliot test cash accept after cleaning left note acceptor. Confirmed working properly. Jams – No Part Used/Cleaning Only - Bill Acceptors/Validator
|
|
| CSDI0014512 | 00444950 | 1549863 | 2026-09-08 | 468.00 | Starbucks 67349 | Rosenberg | TX | ZA-04322 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-03 10:56:00 | 2026-09-03 12:57:00 | 2026-09-04 12:55:00 | 2026-09-04 13:37:00 | 2026-09-04 13:38 | 201-2714-001S (DOOR SOLENOID) |
2026-09-04 Completed: ***TECH#196 CATO***
On site 9/4@12:55p...
2026-09-04 Completed: ***TECH#196 CATO***
On site 9/4@12:55pm. On arrival Door 2 would not open. Found the cable had pulled loose from the distribution PCB. I created some extra salck in the cable and plugged it back in. Tested all doors and showed Alexis how to clear jams in the acceptors, she is new to this store and had some questions. No parts replaced, see photos attached Operational Issues - Improper Handling (Vault doors not secure, additional training needed, minor repairable damage, alignment, etc.)
|
| CSDI0014482 | 00444346 | 1549151 | 2026-09-08 | 936.00 | Starbucks 19869 | Nampa | ID | UG-38512 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-09-01 16:27:00 | 2026-09-01 18:35:00 | 2026-09-02 15:08:00 | 2026-09-02 15:30:00 | 2026-09-02 15:36 |
09/02/2026 Completed: Cleared jam from BA1. Tested with MOD....
09/02/2026 Completed: Cleared jam from BA1. Tested with MOD. Operable Jams – No Part Used/Cleaning Only - Bill Acceptors/Validator
|
|
| CSDI0014464 | 00444039 | 1548921 | 2026-09-08 | 584.79 | Starbucks 67099 | El Paso | TX | ZA-03009 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-09-01 01:40:00 | 2026-09-02 14:48:00 | 2026-09-02 15:37:00 | 2026-09-03 17:32:00 | 2026-09-03 17:33 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
2026-09-03 Completed: Spoke to the manager tony he had the p...
2026-09-03 Completed: Spoke to the manager tony he had the part to fix the handle
I had to call sesami and get a PACN code
Drilled out the old handel and replaced with the new one Abuse - Physical Damage
|
| CSDI0014434 | 00443555 | 1548514 | 2026-09-08 | 935.79 | Starbucks 7348 | Hoboken | NJ | UG-38467 | Smart Safe | SmartSafe | CUSTOMER_DAMAGE | 2026-08-30 16:05:00 | 2026-08-30 17:51:00 | 2026-08-31 11:40:00 | 2026-08-31 12:27:00 | 2026-08-31 12:30 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
08/31/2026 Completed: Door handle not broken
Door handle not...
08/31/2026 Completed: Door handle not broken
Door handle not broken
No replacement of door handle, cancel call/ticket. Non-Device Related Issue - No problem found/Call Cancellation request received too late
|
| CSDI0014423 | 00443428 | 1548358 | 2026-09-08 | 468.00 | Starbucks 11431 | Little Rock | AR | UG-41209 | Smart Safe | SmartSafe | CUSTOMER_ABUSE | 2026-08-29 21:11:00 | 2026-08-30 15:09:00 | 2026-08-31 11:30:00 | 2026-08-31 12:15:00 | 2026-08-31 12:17 |
08/31/2026 Completed: Arrived onsite duplicated issue with s...
08/31/2026 Completed: Arrived onsite duplicated issue with store manager Jamie I took apart and blew out both bill acceptors switched both mei boards as well as bill acceptors after noticing the left one didn't take any bills and the right one was making loud popping noises due to a paper clip that was jammed deep inside the mouth of the right bill acceptor and the left one had an old bill ripped up inside it and a coffee bean after all jams were found and cleared we ran a couple note tests and both bill acceptors are now back online and operating as normal Abuse - Foreign Object – No Part Replaced
|
|
| CSDI0014291 | 00441653 | 1546510 | 2026-09-04 | 936.00 | Starbucks 20391 | Texarkana | AR | ZA-03206 | Smart Safe | SmartSafe | LACK_OF_MAINTENANCE | 2026-08-24 15:51:00 | 2026-08-24 17:47:00 | 2026-08-26 13:08:00 | 2026-08-26 14:21:00 | 2026-08-26 13:25 |
08/26/2026 Completed: Arrived on site and spoke with shift m...
08/26/2026 Completed: Arrived on site and spoke with shift manager Julia, who said that door 2 would not want to lock sometimes. Door 1 would do this very seldomly. I then logged in with PACN code, and began inspecting doors 1 and 2, finding no problems besides the door open/close sensors being pretty dirty. I cleaned them and also opened the solenoid panels on both to inspect their strength. They are operating normally. I then ran voltage checks on both power supplies.
Right: 5.3, 5.3, and 13.3
Left:24, 24, and 24
Afterwards, I opened and closed each door between 15 and 20 times with no issues. Unit is up and open.
|
|
| CSDI0014344 | 00441708 | 1546589 | 2026-09-04 | 1921.83 | Starbucks 52122 | Bartlett | IL | UG-41078 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-24 20:53:00 | 2026-08-25 10:08:00 | 2026-08-26 15:24:00 | 2026-08-26 16:36:00 | 2026-08-26 16:38 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
08/26/2026 Completed: Unit was uao, but mod had removed the ...
08/26/2026 Completed: Unit was uao, but mod had removed the right side BV. Found a penny jammed in entry transport. Mod Katie wanted it replaced it either way due to ongoing issue. Installed new and tested x3. Atm uao.
|
| CSDI0014368 | 00442317 | 1547321 | 2026-09-04 | 1894.77 | Starbucks 2417 | Lee's Summit | MO | UG-38801 | Smart Safe | SmartSafe | OTHER | 2026-08-26 12:40:00 | 2026-08-26 14:49:00 | 2026-08-26 17:34:00 | 2026-08-26 18:06:00 | 2026-08-26 18:10 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
08/26/2026 Completed: Acceptor Failed
Replace The Bill Vali...
08/26/2026 Completed: Acceptor Failed
Replace The Bill Validator
|
| CSDI0014345 | 00441711 | 1546619 | 2026-09-04 | 994.50 | Starbucks 2998 | Bakersfield | CA | ZA-04621 | Smart Safe | SmartSafe | LACK_OF_MAINTENANCE | 2026-08-24 21:43:00 | 2026-08-25 00:56:00 | 2026-08-25 15:51:00 | 2026-08-25 16:19:00 | 2026-08-25 16:23 |
08/25/2026 Completed: Arrived on site and asked for manager....
08/25/2026 Completed: Arrived on site and asked for manager. Manager said its been working since he took a dollar bill piece out of BA. I took them out and cleaned them. I found a piece of a $20 bill and a coffee bean inside one. Put the BA's back in and are working. Safe is up.
|
|
| CSDI0014416 | 00443295 | 1548198 | 2026-09-04 | 777.00 | Starbucks 66185 | El Cajon | CA | UG-43607 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-29 07:07:00 | 2026-08-29 09:46:00 | 2026-08-29 13:50:00 | 2026-08-29 15:05:00 | 2026-08-29 15:10 | 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR) |
08/29/2026 Completed: Before arriving on-site I picked up th...
08/29/2026 Completed: Before arriving on-site I picked up the parts from the San Diego FSL. Upon arrival I spoke with site MOD Ms. Trista who explained that door 1 on safe would not close properly. Upon inspection I found 3 rolls of coin jammed in the outer back of door one preventing the door from closing all the way. After removing the the rolls I was able to get door to close properly. I tested the door sensors and silonoid multiple time with no issues. The door must be pushed up when closing to help get door in the correct position. Tested the door and silonoid a few times more with Ms. Trista ro make sure the door is still working properly.
|
| CSDI0014334 | 00441550 | 1546461 | 2026-09-04 | 1863.33 | Starbucks 14369 | Yonkers | NY | UG-39795 | Smart Safe | SmartSafe | OTHER | 2026-08-24 12:10:00 | 2026-08-24 17:15:00 | 2026-08-25 11:14:00 | 2026-08-25 12:01:00 | 2026-08-25 12:06 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
08/25/2026 Completed: On arrivel found 2 bill accepter on s...
08/25/2026 Completed: On arrivel found 2 bill accepter on site I tested the bill accepters that were on the safe both faulty replace both bill accepter tested successfully sea tracking on both bill accepters
|
| CSDI0014221 | 00441627 | 1546501 | 2026-09-04 | 1186.50 | Starbucks 5729 | San Bruno | CA | UG-43783 | Smart Safe | SmartSafe | OTHER | 2026-08-24 15:03:00 | 2026-08-24 17:19:00 | 2026-08-26 12:05:00 | 2026-08-27 19:57:00 | 2026-08-27 20:02 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4), 644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
08/27/2026 Completed: Upon arrival after checking in with Ma...
08/27/2026 Completed: Upon arrival after checking in with Maura I was given access to the safe I found the parts required were onsite I replaced the modem antenna and power cables as well as the right BV found the old modem was actually working the site actually had a bad outlet. . Unfortunately when verifying communication with Donald at deposita I found the modem was DOA extensive troubleshooting was performed he decided to reinstall the old modem and reconfigure it. Safe is now online and in service. Dropped off tidel provided Starbucks parts same day.
|
| CSDI0014399 | 00442914 | 1547931 | 2026-09-02 | 601.50 | Starbucks 5987 | Atascadero | CA | UG-43721 | Smart Safe | SmartSafe | LACK_OF_MAINTENANCE | 2026-08-28 07:36:00 | 2026-08-28 10:57:00 | 2026-08-29 17:27:00 | 2026-08-29 18:02:00 | 2026-08-29 18:04 | 205-4086-001S (SOLENOID ASSY W/ ANTI-THEFT) |
08/29/2026 Completed: Bottom Drawer was hard to open and clo...
08/29/2026 Completed: Bottom Drawer was hard to open and close. Found a Grey cable hanging down inside above the drawer, looked like it was hooking on some of the contents in the drawer. It was not in one of its security mounts. Fixed that. Drawer is loaded with coins and is weighted down i little in front. Advised customer of that and to just lift the handle up some while opening or closing the drawer. She also said they were having problems with the acceptor's. Check both and they had coffee beans in them. Took those out, cleaned and both tested successfully by manager
|
| CSDI0014393 | 00442839 | 1547785 | 2026-09-02 | 601.50 | Starbucks 47311 | San Jose | CA | UG-43943 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-27 17:52:00 | 2026-08-27 19:17:00 | 2026-08-28 12:12:00 | 2026-08-28 13:00:00 | 2026-08-28 13:05 |
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SC...
644-0117-434R (Refurbished MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
08/28/2026 Completed: Arrived on site, started troubleshooti...
08/28/2026 Completed: Arrived on site, started troubleshooting issues with safe. Both Bvs were not communicating and printer was not communicating. Reseated the both bvs and one had a coin jammed. Cleared the jam and and did a power reset. Both bvs where not ready and printer was ready. Tested both Bvs with MOD and both are now working properly. Safe is up and running.
|
| CSDI0014380 | 00442496 | 1547425 | 2026-09-02 | 601.50 | Starbucks 66573 | North Branford, | CT | ZA-02800 | Smart Safe | SmartSafe | OTHER | 2026-08-26 20:37:00 | 2026-08-27 11:12:00 | 2026-08-28 15:28:00 | 2026-08-28 15:41:00 | 2026-08-28 10:24 |
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 6...
210-0510-001S (PCB CONTROL PANEL (NON CUSTOMER SPECIFIC)), 633-0020-007S (DISPLAY W/BACKLIGHT BULB), 642-0002-101S (POWER SUPPLY SERIES 4 RIGHT SIDE & S5), 642-0015-101S (POWER SUPPLY SERIES 4 LEFT SIDE)
|
08/28/2026 Completed: Arrived on site safe was up and runnin...
08/28/2026 Completed: Arrived on site safe was up and running with no visible issues. Spoke with Manager therese who says issue had been resolved recently. Call closed, safe is up
|
| CSDI0014359 | 00442086 | 1547032 | 2026-09-02 | 468.00 | Starbucks 2863 | Piscataway | NJ | UG-38846 | Smart Safe | SmartSafe | OTHER | 2026-08-25 19:46:00 | 2026-08-25 20:40:00 | 2026-08-26 14:46:00 | 2026-08-26 15:06:00 | 2026-08-26 15:10 |
08/26/2026 Completed: Checked machine for any problems. Bord...
08/26/2026 Completed: Checked machine for any problems. Border on the right side of safe causing door not to open .see pictures
|
|
| CSDI0014398 | 00442894 | 1547875 | 2026-09-02 | 543.00 | Starbucks 2384 | Oakwood | OH | UG-38699 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-28 06:23:00 | 2026-08-28 07:06:00 | 2026-08-29 09:45:00 | 2026-08-29 10:00:00 | 2026-08-29 10:00 | 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR) |
2026-08-29 Completed: Upon arrival drop vault solenoid can b...
2026-08-29 Completed: Upon arrival drop vault solenoid can be heard but handle will not budge.
Activated the solenoid for drop vault; whilst channeling the spirit of Thor, struck the door once in the center with a light tap from the Mallet of Deadblow.
Door is now unstuck.
Tested open close several times.
Unit is fully functional
|
| CSDI0014386 | 00442551 | 1547551 | 2026-09-02 | 468.00 | Starbucks 6998 | Lakewood | CO | UG-44128 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-27 07:58:00 | 2026-08-27 11:40:00 | 2026-08-28 13:47:00 | 2026-08-28 14:43:00 | 2026-08-28 14:43 |
2026-08-28 Completed: Started with looking for jammed bill i...
2026-08-28 Completed: Started with looking for jammed bill in bill acceptor assembly, then did maintenance to both bill acceptor assemblies, tested, left side bill acceptor was still having issues, after swapping BNF and tested both bill acceptors started working properly, tested, working fine
|
|
| CSDI0014384 | 00442518 | 1547471 | 2026-09-02 | 468.00 | Starbucks 10700 | Arlington | TX | ZA-03125 | Smart Safe | SmartSafe | OTHER | 2026-08-27 04:44:00 | 2026-08-27 10:39:00 | 2026-08-28 11:17:00 | 2026-08-28 11:22:00 | 2026-08-28 11:26 |
2026-08-28 Completed: Upon arrival exited vehicle and entere...
2026-08-28 Completed: Upon arrival exited vehicle and entered the building and then spoke with the MOD. They said they called and canceled the call yesterday and it is working correctly. Spoke with Rena on site and closed the call.
|
|
| CSDI0014333 | 00441548 | 1546672 | 2026-09-02 | 601.50 | Starbucks 29700 | Paramount | CA | UG-44217 | Smart Safe | SmartSafe | OTHER | 2026-08-24 12:05:00 | 2026-08-25 12:04:00 | 2026-08-25 14:49:00 | 2026-08-25 15:22:00 | 2026-08-25 15:24 |
201-2714-002S (SOLENOID DROP VAULT/PED BASE/SIDE VAULT), 632...
201-2714-002S (SOLENOID DROP VAULT/PED BASE/SIDE VAULT), 632-0012-010S (SENSOR KIT VAULT DOORS (2 PER))
|
08/25/2026 Completed: Found latch disassembled Found nut and...
08/25/2026 Completed: Found latch disassembled Found nut and reassembled at this point had sit test 3 times
No parts used
|
| CSDI0014314 | 00441231 | 1546157 | 2026-09-02 | 601.50 | Starbucks 8394 | Franklin | TN | UG-38046 | Smart Safe | SmartSafe | NO_PROBLEM_FOUND | 2026-08-23 09:49:00 | 2026-08-23 16:41:00 | 2026-08-24 10:42:00 | 2026-08-24 10:57:00 | 2026-08-24 11:00 | 201-2714-003S (SOLENOID BILL ACCEPTOR & MAINTENANCE DOOR) |
08/24/2026 Completed: Tech arrived and met with mod who desc...
08/24/2026 Completed: Tech arrived and met with mod who described having no issues with vault this morning. Opened and closed door several times without fault. Inspected lock mechanism and no faults found. Unit uao.
1Z7611409053901059
FH 8/24/26.
|
| CSDI0014239 | 00442012 | 1546881 | 2026-09-02 | 468.00 | Starbucks 68636 | Childress | TX | ZA-03013 | Smart Safe | SmartSafe | OTHER | 2026-08-25 15:42:00 | 2026-08-25 17:51:00 | 2026-08-26 15:30:00 | 2026-08-26 17:26:00 | 2026-08-26 17:27 |
2026-08-26 Completed: MOD said the machine is off line. I ch...
2026-08-26 Completed: MOD said the machine is off line. I checked the network tests. No connection. I opened the courior door. I saw the modem was not powered on at all. I called Deposita. They had shipped a new modem. Customer gave me the Fedex box. I removed the old modem. I installed the new modem. Ran the network tests. Safe is back on line.
|
|
| CSDI0014360 | 00442087 | 1547206 | 2026-09-02 | 468.00 | Starbucks 25041 | Parma | OH | UG-38363 | Smart Safe | SmartSafe | OTHER | 2026-08-25 19:59:00 | 2026-08-26 10:09:00 | 2026-08-27 07:26:00 | 2026-08-27 07:32:00 | 2026-08-27 07:32 | 2026-08-27 Completed: Problem was resolved before arriving. | |
| CSDI0014331 | 00441519 | 1546444 | 2026-09-02 | 468.00 | Starbucks 11281 | Forest Park | OH | UG-38059 | Smart Safe | SmartSafe | OTHER | 2026-08-24 11:22:00 | 2026-08-24 16:07:00 | 2026-08-25 09:27:00 | 2026-08-25 10:23:00 | 2026-08-25 10:23 |
2026-08-25 Completed: Arrived at location modem has power li...
2026-08-25 Completed: Arrived at location modem has power light and one light on cat5 connection not connecting to server checked xml pos test and client ftp both failed. Contacted Deposita and spoke with Jacob he said to close call and they would ship out a new modem. I was directed to have manager Jeff Tell to call in a new ticket and Deposita was sending a modem to location.
|
|
| CSDI0014358 | 00442085 | 1547006 | 2026-09-02 | 468.00 | Starbucks 8295 | Tampa | FL | UG-38181 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-25 19:35:00 | 2026-08-26 10:43:00 | 2026-08-26 16:35:00 | 2026-08-26 16:46:00 | 2026-08-26 16:51 |
08/26/2026 Completed: Arrived onsite found $20 jammed inside...
08/26/2026 Completed: Arrived onsite found $20 jammed inside and took it out cleaned it and had manager on duty test all worked out for the best.
|
|
| CSDI0014356 | 00442056 | 1546943 | 2026-09-02 | 660.00 | Starbucks 3388 | Gig Harbor | WA | ZA-02809 | Smart Safe | SmartSafe | NO_PROBLEM_FOUND | 2026-08-25 17:43:00 | 2026-08-25 19:31:00 | 2026-08-27 16:32:00 | 2026-08-27 16:50:00 | 2026-08-27 16:52 | 502-1363-001S (HANDLE BALL BILL VAL DOOR) |
08/27/2026 Completed: Arrived on site, gained access from MO...
08/27/2026 Completed: Arrived on site, gained access from MOD. Found ball handled unscrewed and very loose. Was able to re install ball handle and tighten down to ensure it wouldn't come out. Tested with site with no issues. New ball handle was not used, returning part asap
|
| CSDI0014361 | 00442103 | 1547060 | 2026-09-02 | 543.00 | Starbucks 6485 | Carrollton | TX | ZA-03112 | Smart Safe | SmartSafe | NO_ISSUE_ON_ARRIVAL | 2026-08-25 21:58:00 | 2026-08-26 11:07:00 | 2026-08-26 16:35:00 | 2026-08-26 17:21:00 | 2026-08-26 17:26 |
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4...
644-0117-434S (MEI 66 US HEAD & BEZEL BNF ADV SCM & SERIES 4)
|
2026-08-26 Completed: On arrival, Raven explained that issue...
2026-08-26 Completed: On arrival, Raven explained that issue with both BAs started monday night and progressively got worse until acceptors would not pull in and cash. On inspection, found Foreign objects in both bunch note feeders. Purple objects were sticky and had to be scraped from transport. Removed all foreign contaminants and cleaned bill acceptors. Installed back into safe and let initialize. Tested both acceptors with bill authentication successfully. Raven then tested with deposit without issues. Advised to instruct employees not to prep on counter above safe. Safe is back in full operation. Job complete.
|
| CSDI0014406 | 00443126 | 1548044 | 2026-09-02 | 526.50 | Starbucks 56707 | River Grove | IL | UG-38922 | Smart Safe | SmartSafe | NO_ISSUE_ON_ARRIVAL | 2026-08-28 13:58:00 | 2026-08-28 15:37:00 | 2026-08-28 17:59:00 | 2026-08-28 18:35:00 | 2026-08-28 18:38 |
08/28/2026 Completed: Safe was in service on arrival with th...
08/28/2026 Completed: Safe was in service on arrival with the left BA not working. Found a $5 bill jammed in the left BA. Removed jam and cleaned both BA's. Had manager test inserting bills into the left BA successfully. UAO
|
|
| CSDI0014357 | 00442073 | 1546973 | 2026-09-02 | 468.00 | Starbucks 63521 | Tonawanda | NY | UG-39669 | Smart Safe | SmartSafe | CUSTOMER_FIXABLE | 2026-08-25 18:36:00 | 2026-08-25 19:33:00 | 2026-08-26 09:21:00 | 2026-08-26 10:01:00 | 2026-08-26 10:06 |
08/26/2026 Completed: Mod Anthony. Upon arrival mod stated t...
08/26/2026 Completed: Mod Anthony. Upon arrival mod stated the left acceptor wouldn’t take notes. After gaining access I found a jammed note on left acceptor. Removed acceptor then removed note. Placed note in vault for armored. I then pulled and cleaned the other acceptor. I then asked mod to drop and he was able to without issue. Unit is up and open.
|
Technician Photos